skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Experimental results with hydrocarbon mixtures in domestic refrigerator/freezers

Conference ·
OSTI ID:87488
; ;  [1]
  1. Univ. of Maryland, College Park, MD (United States). Center for Environmental Energy Engineering

With propane/n-butane blends, energy savings up to 6% were achieved in a domestic refrigerator/freezer compared to the baseline test with R-12. The hydrocarbon mixtures were tested as drop-in substitutes. All the hardware remained the same, only the capillary tube was lengthened to control the flow rate. The additional capillary tube length, the blend concentration, and the charge were adjusted to determine the optimum performance. The best result of 2.29 kWh/day was achieved with a blend of 70% R-290 and 30% R-600, 70 g of charge, and an additional capillary tube length of 5 ft.

OSTI ID:
87488
Report Number(s):
CONF-950104-; TRN: IM9535%%119
Resource Relation:
Conference: American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) winter meeting and exhibition, Chicago, IL (United States), 28 Jan - 1 Feb 1995; Other Information: PBD: 1995; Related Information: Is Part Of ASHRAE transactions 1995. Volume 101, Part 1; PB: 1517 p.
Country of Publication:
United States
Language:
English