The BaBar detector has operated over 2000 m{sup 2} of Resistive Plates Chambers (RPCs) as muon and neutral hadron detectors since 1999. Most of the original RPC production have lost significant efficiency and many are now completely inefficient. Both the linseed oil used to coat the inner surfaces and the graphite coating on the outer surfaces are implicated as contributors to the efficiency loss which was accelerated by the operation of the RPCs at 29 to 34 C during the first summer. RPCs from 2 more recent production runs have been installed and tested. The most recent RPCs have exhibited stable efficiencies and high voltage plateaus during the first 8 months of service. Some have shown increased dark currents and noise rates.

Research Organization:
SLAC National Accelerator Lab., Menlo Park, CA (United States)
Sponsoring Organization:
USDOE Office of Science (SC)
DOE Contract Number:
AC02-76SF00515
OSTI ID:
839838
Report Number(s):
SLAC-PUB-11098; TRN: US0503366
Country of Publication:
United States
Language:
English

Similar Records

Mechanisms Affecting Performance of the BaBar Resistive Plate Chambers and Searches for Remediation
Technical Report · Fri Sep 19 00:00:00 EDT 2003 · OSTI ID:839838

Performance of 2nd Generation BaBar Resistive Plate Chambers
Journal Article · Tue Jul 12 00:00:00 EDT 2005 · Nuclear Instruments and Methods in Physics Research, Section A · OSTI ID:839838

Performance and Aging Studies of BaBar Resistive Plate Chambers
Conference · Fri Oct 13 00:00:00 EDT 2006 · Nucl.Phys.Proc.Suppl.158:139-142,2006 · OSTI ID:839838