Title: A Superstrong Adjustable Permanent Magnet for the Final Focus Quadrupole in a Linear Collider

Technical Report ·
DOI:https://doi.org/10.2172/839805· OSTI ID:839805

A super strong permanent magnet quadrupole (PMQ) was fabricated and tested. It has an integrated strength of 28.5T with overall length of 10 cm and a 7mm bore radius. The final focus quadrupole of a linear collider needs a variable focal length. This can be obtained by slicing the magnet into pieces along the beamline direction and rotating these slices. But this technique may lead to movement of the magnetic center and introduction of a skew quadrupole component when the strength is varied. A ''double ring structure'' can ease these effects. A second prototype PMQ, containing thermal compensation materials and with a double ring structure, has been fabricated. Worm gear is selected as the mechanical rotating scheme because the double ring structure needs a large torque to rotate magnets. The structure of the second prototype PMQ is shown.

Research Organization:
SLAC National Accelerator Lab., Menlo Park, CA (United States)
Sponsoring Organization:
USDOE Office of Science (SC)
DOE Contract Number:
AC02-76SF00515
OSTI ID:
839805
Report Number(s):
SLAC-PUB-10877; TRN: US0503407
Country of Publication:
United States
Language:
English

Similar Records

Superstrong Adjustable Permanent Magnet for a Linear Collider Final Focus
Technical Report · Mon Dec 06 00:00:00 EST 2004 · OSTI ID:839805

A Super Strong Permanent Magnet Quadrupole for the Final Focus in a Linear Collider
Technical Report · Mon Dec 06 00:00:00 EST 2004 · OSTI ID:839805

Super Strong Permanent Magnet Quadrupole for a Linear Collider
Technical Report · Thu Feb 19 00:00:00 EST 2004 · OSTI ID:839805