skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: 9W-12W, 8H and 10H Cell, Rack Pan, and Air Tunnel Inspections for the Safe Deactivation NCSE

Technical Report ·
DOI:https://doi.org/10.2172/835622· OSTI ID:835622

The cell, rack pan, Warm Canyon Air Tunnel (WCAT) and Hot Canyon Air Tunnel (HCAT) inspections did not reveal significant deposits or accumulation of fissile material. Nor were there any depressions, except the sumps, that exceeded the limits of 2 inch x 6 inch in 9W-12W or 20 inch x 35 inch in 8H or 10H. After filling the sumps and isolating the liquid sources, the cells, rack pans, and air tunnels meet the requirements for criticality safety as described in the NCSE.

Research Organization:
Savannah River Site (SRS), Aiken, SC (United States)
Sponsoring Organization:
US Department of Energy (US)
DOE Contract Number:
AC09-96SR18500
OSTI ID:
835622
Report Number(s):
WSRC-TR-2004-00510; TRN: US0500125
Resource Relation:
Other Information: PBD: 1 Sep 2004
Country of Publication:
United States
Language:
English