Title: Pressure Drop Versus Flow Rate Analysis of the Limited Streamer Tube Gas System of the BaBar Muon Detector Upgrade

Abstract

It has been proposed that Limited Streamer Tubes (LST) be used in the current upgrade of the muon detector in the BaBar detector. An LST consists of a thin silver plated wire centered in a graphite-coated cell. One standard LST tube consists of eight such cells, and two or three such tubes form an LST module. Under operation, the cells are filled with a gas mixture of CO{sub 2}, argon and isobutane. During normal operation of the detector, the gas will be flushed out of the system at a constant low rate of one volume change per day. During times such as installation, however, it is often desired to flush and change the LST gas volumes very rapidly, leading to higher than normal pressure which may damage the modules. This project studied this pressure as a function of flow rate and the number of modules that are put in series in search of the maximal safe flow rate at which to flush the modules. Measurements of pressure drop versus flow rate were taken using a flow meter and a pressure transducer on configurations of one to five modules put in series. Minimal Poly-Flo tubing was used for all connections betweenmore » test equipment and modules. They contributed less than 25% to all measurements. A ratio of 0.00022 {+-} 0.00001 mmHg per Standard Cubic Centimeter per Minute (SCCM) per module was found, which was a slight overestimate since it included the contributions from the tubing connections. However, for the purpose of finding a flow rate at which the modules can be safely flushed, this overestimate acts as a safety cushion. For a standard module with a volume of 16 liters and a known safe overpressure of 2 inches of water, the ratio translates into a flow rate of 17000 {+-} 1000SCCM and a time requirement of 56 {+-} 5 seconds to flush an entire module.« less

Authors:
Publication Date:
Research Org.:
Stanford Linear Accelerator Center, Menlo Park, CA (US)
Sponsoring Org.:
USDOE Office of Science (US)
OSTI Identifier:
833113
Report Number(s):
SLAC-TN-04-059
TRN: US0406568
DOE Contract Number:  
AC03-76SF00515
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 3 Sep 2004
Country of Publication:
United States
Language:
English
Subject:
72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS; 2-METHYLPROPANE; ARGON; FLOW RATE; METERS; MIXTURES; MUONS; PRESSURE DROP; SAFETY; SILVER; TRANSDUCERS; WATER

Citation Formats

Yi, M. Pressure Drop Versus Flow Rate Analysis of the Limited Streamer Tube Gas System of the BaBar Muon Detector Upgrade. United States: N. p., 2004. Web. doi:10.2172/833113.
Yi, M. Pressure Drop Versus Flow Rate Analysis of the Limited Streamer Tube Gas System of the BaBar Muon Detector Upgrade. United States. doi:10.2172/833113.
Yi, M. Fri . "Pressure Drop Versus Flow Rate Analysis of the Limited Streamer Tube Gas System of the BaBar Muon Detector Upgrade". United States. doi:10.2172/833113. https://www.osti.gov/servlets/purl/833113.
@article{osti_833113,
title = {Pressure Drop Versus Flow Rate Analysis of the Limited Streamer Tube Gas System of the BaBar Muon Detector Upgrade},
author = {Yi, M},
abstractNote = {It has been proposed that Limited Streamer Tubes (LST) be used in the current upgrade of the muon detector in the BaBar detector. An LST consists of a thin silver plated wire centered in a graphite-coated cell. One standard LST tube consists of eight such cells, and two or three such tubes form an LST module. Under operation, the cells are filled with a gas mixture of CO{sub 2}, argon and isobutane. During normal operation of the detector, the gas will be flushed out of the system at a constant low rate of one volume change per day. During times such as installation, however, it is often desired to flush and change the LST gas volumes very rapidly, leading to higher than normal pressure which may damage the modules. This project studied this pressure as a function of flow rate and the number of modules that are put in series in search of the maximal safe flow rate at which to flush the modules. Measurements of pressure drop versus flow rate were taken using a flow meter and a pressure transducer on configurations of one to five modules put in series. Minimal Poly-Flo tubing was used for all connections between test equipment and modules. They contributed less than 25% to all measurements. A ratio of 0.00022 {+-} 0.00001 mmHg per Standard Cubic Centimeter per Minute (SCCM) per module was found, which was a slight overestimate since it included the contributions from the tubing connections. However, for the purpose of finding a flow rate at which the modules can be safely flushed, this overestimate acts as a safety cushion. For a standard module with a volume of 16 liters and a known safe overpressure of 2 inches of water, the ratio translates into a flow rate of 17000 {+-} 1000SCCM and a time requirement of 56 {+-} 5 seconds to flush an entire module.},
doi = {10.2172/833113},
journal = {},
number = ,
volume = ,
place = {United States},
year = {2004},
month = {9}
}

Technical Report:

Save / Share: