Corrosion Behavior of 304 Stainless Steel in High Temperature, Hydrogenated Water
The corrosion behavior of an austenitic stainless steel (UNS S30400) has been characterized in a 10,000 hour test conducted in hydrogenated, ammoniated water at 260 C. The corrosion kinetics were observed to follow a parabolic rate dependency, the parabolic rate constant being determined by chemical descaling to be 1.16 mg dm{sup -2} hr{sup -1/2}. X-ray photoelectron spectroscopy, in combination with argon ion milling and target factor analysis, was applied to provide an independent estimate of the rate constant that agreed with the gravimetric result. Based on the distribution of the three oxidized alloying constituents (Fe, Cr, Ni) with respect to depth and elemental state, it was found that: (a) corrosion occurs in a non-selective manner, and (b) the corrosion film consists of two spinel oxide layers--a ferrite-based outer layer (Ni{sub 0.2}Fe{sub 0.8})(Fe{sub 0.95}Cr{sub 0.05}){sub 2}O{sub 4} on top of a chromite-based inner layer (Ni{sub 0.2}Fe{sub 0.8})(Cr{sub 0.7}Fe{sub 0.3}){sub 2}O{sub 4}. These compositions agree closely with the solvi phases created by immiscibility in the Fe{sub 3}O{sub 4}-FeCr{sub 2}O{sub 4} binary, implying that immiscibility plays an important role in the phase separation process.
- Research Organization:
- Lockheed Martin Corporation, Schenectady, NY 12301 (US)
- Sponsoring Organization:
- US Department of Energy (US)
- DOE Contract Number:
- AC12-00SN39357
- OSTI ID:
- 821681
- Report Number(s):
- LM-01K046; TRN: US200411%%661
- Resource Relation:
- Other Information: PBD: 4 May 2001
- Country of Publication:
- United States
- Language:
- English
Similar Records
Zinc Treatment Effects on Corrosion Behavior of 304 Stainless Steel in High Temperature, Hydrogenated Water
Analysis of oxide film formed on type 304 stainless steel in 288 C water containing oxygen, hydrogen, and hydrogen peroxide