Title: BABAR IFR Replacement R& D

Technical Report ·
DOI:https://doi.org/10.2172/815638· OSTI ID:815638

The Instrumented Flux Return (IFR) of the BaBar detector will soon need to be replaced by a more robust muon detection system. Scintillator bars with embedded Wavelength Shifting (WLS) fibers and Limited Streamer Tubes are two replacement technology options. The scintillator bars are tested for attenuation length; and causes for the large width of the Photo Multiplier Tube (PMT) signal are analyzed by Monte Carlo simulation. Cooling techniques for Avalanche Photo Diodes (APD) are investigated. The fairly high attenuation length coupled with the narrow PMT signal make the scintillator a viable option for a muon detecting system. Continuing work will focus on increasing timing resolution using an APD to read the signal from the WLS fibers, and investigating the lifetime of the APD. The ability to read a signal from the LST on external copper strips is tested and signals are found to be clearly distinguishable from noise. The voltage is compared to count rate to find that the optimal operating voltage for the LST used is 4600V. Further studies will be conducted in strip readout and fabrication as well as in the optimal isobutane content in the gas mixture that flows through the tube.

Research Organization:
SLAC National Accelerator Lab., Menlo Park, CA (United States)
Sponsoring Organization:
USDOE Office of Science (US)
DOE Contract Number:
AC03-76SF00515
OSTI ID:
815638
Report Number(s):
SLAC-TN-03-008; TRN: US0304747
Resource Relation:
Other Information: PBD: 5 Sep 2003
Country of Publication:
United States
Language:
English