Title: Technical evaluation of the adequacy of station electric distribution systems voltages for the Calvert Cliffs Nuclear Power Plant, Units 1 and 2. Docket Nos. 50-317, 50-318

Abstract

This report documents the technical evaluation of the adequacy of the station electric distribution system voltages for the Calvert Cliffs Nuclear Power Plant, Units 1 and 2. The evaluation is to determine if the onsite distribution system in conjunction with the offsite power sources has sufficient capacity to automatically start and operate all Class 1E loads within the equipment voltage ratings under certain conditions established by the Nuclear Regulatory Commission. The analyses submitted demonstrate that adequate voltage will be supplied to the Class 1E equipment under worst case conditions.

Authors:
Publication Date:
Research Org.:
Lawrence Livermore National Lab., CA (USA)
Sponsoring Org.:
USDOE
OSTI Identifier:
8141467
Report Number(s):
UCID-19133
ON: DE82013310
DOE Contract Number:
W-7405-ENG-48
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; CALVERT CLIFFS-1 REACTOR; ELECTRICAL EQUIPMENT; POWER SUPPLIES; CALVERT CLIFFS-2 REACTOR; PERFORMANCE; RELIABILITY; ELECTRONIC EQUIPMENT; EQUIPMENT; POWER REACTORS; PWR TYPE REACTORS; REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS; 210200* - Power Reactors, Nonbreeding, Light-Water Moderated, Nonboiling Water Cooled

Citation Formats

Selan, J. C. Technical evaluation of the adequacy of station electric distribution systems voltages for the Calvert Cliffs Nuclear Power Plant, Units 1 and 2. Docket Nos. 50-317, 50-318. United States: N. p., 1982. Web. doi:10.2172/8141467.
Selan, J. C. Technical evaluation of the adequacy of station electric distribution systems voltages for the Calvert Cliffs Nuclear Power Plant, Units 1 and 2. Docket Nos. 50-317, 50-318. United States. doi:10.2172/8141467.
Selan, J. C. Fri . "Technical evaluation of the adequacy of station electric distribution systems voltages for the Calvert Cliffs Nuclear Power Plant, Units 1 and 2. Docket Nos. 50-317, 50-318". United States. doi:10.2172/8141467. https://www.osti.gov/servlets/purl/8141467.
@article{osti_8141467,
title = {Technical evaluation of the adequacy of station electric distribution systems voltages for the Calvert Cliffs Nuclear Power Plant, Units 1 and 2. Docket Nos. 50-317, 50-318},
author = {Selan, J. C.},
abstractNote = {This report documents the technical evaluation of the adequacy of the station electric distribution system voltages for the Calvert Cliffs Nuclear Power Plant, Units 1 and 2. The evaluation is to determine if the onsite distribution system in conjunction with the offsite power sources has sufficient capacity to automatically start and operate all Class 1E loads within the equipment voltage ratings under certain conditions established by the Nuclear Regulatory Commission. The analyses submitted demonstrate that adequate voltage will be supplied to the Class 1E equipment under worst case conditions.},
doi = {10.2172/8141467},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Fri Apr 09 00:00:00 EST 1982},
month = {Fri Apr 09 00:00:00 EST 1982}
}

Technical Report:

Save / Share: