Title: DWPF Melter No.2 Prototype Bus Bar Test Report

Abstract

Characterization and performance testing of a prototype DWPF Melter No.2 Dome Heater Bus Bar are described. The prototype bus bar was designed to address the design features of the existing system which may have contributed to water leaks on Melter No.1. Performance testing of the prototype revealed significant improvement over the existing design in reduction of both bus bar and heater connection maximum temperature, while characterization revealed a few minor design and manufacturing flaws in the bar. The prototype is recommended as an improvement over the existing design. Recommendations are also made in the area of quality control to ensure that critical design requirements are met.

Authors:
Publication Date:
Research Org.:
Savannah River Site (US)
Sponsoring Org.:
US Department of Energy (US)
OSTI Identifier:
809397
Report Number(s):
WSRC-TR-2001-00171
TRN: US0302455
DOE Contract Number:  
AC09-96SR18500
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 26 Mar 2003
Country of Publication:
United States
Language:
English
Subject:
12 MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; RADIOACTIVE WASTE FACILITIES; CERAMIC MELTERS; DESIGN; HEATERS; PERFORMANCE TESTING; QUALITY CONTROL; RADIOACTIVE WASTE PROCESSING

Citation Formats

Gordon, J. DWPF Melter No.2 Prototype Bus Bar Test Report. United States: N. p., 2003. Web. doi:10.2172/809397.
Gordon, J. DWPF Melter No.2 Prototype Bus Bar Test Report. United States. doi:10.2172/809397.
Gordon, J. Wed . "DWPF Melter No.2 Prototype Bus Bar Test Report". United States. doi:10.2172/809397. https://www.osti.gov/servlets/purl/809397.
@article{osti_809397,
title = {DWPF Melter No.2 Prototype Bus Bar Test Report},
author = {Gordon, J},
abstractNote = {Characterization and performance testing of a prototype DWPF Melter No.2 Dome Heater Bus Bar are described. The prototype bus bar was designed to address the design features of the existing system which may have contributed to water leaks on Melter No.1. Performance testing of the prototype revealed significant improvement over the existing design in reduction of both bus bar and heater connection maximum temperature, while characterization revealed a few minor design and manufacturing flaws in the bar. The prototype is recommended as an improvement over the existing design. Recommendations are also made in the area of quality control to ensure that critical design requirements are met.},
doi = {10.2172/809397},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Mar 26 00:00:00 EST 2003},
month = {Wed Mar 26 00:00:00 EST 2003}
}

Technical Report:

Save / Share: