Field observations, preliminary model analysis, and aquifer thermal efficiency: Cyclic injection, storage, and withdrawal of heated water in a sandstone aquifer at St. Paul, Minnesota. Professional paper
Technical Report
·
OSTI ID:80637
The report describes the (1) analysis of field observations for aquifer characterization and observation network design, (2) preliminary model analysis to determine model sensitivity to hydraulic and thermal characteristics and to facilitate final model design, and (3) aquifer thermal efficiency. The report is the first of three reports that describes the potential for thermal-energy storage within the Franconia-Ironton-Galesville aquifer located beneath the St. Paul campus of the University of Minnesota.
- Research Organization:
- Geological Survey, Alexandria, VA (United States)
- OSTI ID:
- 80637
- Report Number(s):
- PB-95-229209/XAB; USGS-PP-1530-A; TRN: 51992974
- Resource Relation:
- Other Information: DN: Also available from Supt. of Docs. Library of Congress catalog card No. 93-23497; PBD: 1993
- Country of Publication:
- United States
- Language:
- English
Similar Records
Anisotropy in the Ironton and Galesville sandstones near a thermal-energy-storage well, St. Paul, Minnesota
Field-test results of aquifer thermal energy storage at St. Paul, Minnesota
The University of Minnesota aquifer thermal energy storage (ATES) field test facility -- system description, aquifer characterization, and results of short-term test cycles
Journal Article
·
· Ground Water; (United States)
·
OSTI ID:80637
Field-test results of aquifer thermal energy storage at St. Paul, Minnesota
Journal Article
·
Mon Aug 01 00:00:00 EDT 1994
· Journal of Energy Engineering; (United States)
·
OSTI ID:80637
+1 more
The University of Minnesota aquifer thermal energy storage (ATES) field test facility -- system description, aquifer characterization, and results of short-term test cycles
Technical Report
·
Sat Jun 01 00:00:00 EDT 1991
·
OSTI ID:80637
+9 more