Title: Tank 241-AZ-101 Mixer Pump Test Vapor Sampling and Analysis Plan

Technical Report ·
DOI:https://doi.org/10.2172/802997· OSTI ID:802997

This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification. Sampling will be performed in accordance with Tank 241-AZ-101 Mixer Pump Test Data Quality Objective (Banning 1999) and Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications.

Research Organization:
CH2M Hill Hanford Group, Inc., Richland, WA (United States)
Sponsoring Organization:
ENVIRONMENTAL MANAGEMENT (US)
DOE Contract Number:
AC27-99RL14047
OSTI ID:
802997
Report Number(s):
RPP-5534, Rev.2; ECN-657320; TRN: US0300426
Resource Relation:
Other Information: PBD: 10 Apr 2000
Country of Publication:
United States
Language:
English