Title: RADIATION DOSIMETRY OF THE PRESSURE VESSEL INTERNALS OF THE HIGH FLUX BEAM REACTOR.

Abstract

In preparation for the eventual decommissioning of the High Flux Beam Reactor after the permanent removal of its fuel elements from the Brookhaven National Laboratory, both measurements and calculations of the decay gamma-ray dose rate have been performed for the reactor pressure vessel and vessel internal structures which included the upper and lower thermal shields, the transition plate, and the control rod blades. The measurements were made using Red Perspex{trademark} polymethyl methacrylate high-level film dosimeters, a Radcal ''peanut'' ion chamber, and Eberline's high-range ion chamber. To compare with measured gamma-ray dose rate, the Monte Carlo MCNP code and geometric progressive Microshield code were used to model the gamma transport and dose buildup.

Authors:
; ; ;
Publication Date:
Research Org.:
Brookhaven National Lab., Upton, NY (US)
Sponsoring Org.:
USDOE Office of Energy Research (ER) (US)
OSTI Identifier:
801700
Report Number(s):
BNL-69339
R&D Project: EST003NEFA; KB0301042; TRN: US0203990
DOE Contract Number:  
AC02-98CH10886
Resource Type:
Conference
Resource Relation:
Conference: 11TH INTERNATIONAL SYMPOSIUM ON REACTOR DOSIMETRY, BRUSSELS (BE), 08/18/2002--08/23/2002; Other Information: PBD: 18 Aug 2002
Country of Publication:
United States
Language:
English
Subject:
22 GENERAL STUDIES OF NUCLEAR REACTORS; BUILDUP; CONTROL ELEMENTS; DECAY; DECOMMISSIONING; DOSE RATES; DOSEMETERS; DOSIMETRY; FUEL ELEMENTS; METHACRYLATES; PRESSURE VESSELS; THERMAL SHIELDS; TRANSPORT

Citation Formats

HOLDEN,N.E., RECINIELLO,R.N., HU,J.P., and RORER,D.C. RADIATION DOSIMETRY OF THE PRESSURE VESSEL INTERNALS OF THE HIGH FLUX BEAM REACTOR.. United States: N. p., 2002. Web.
HOLDEN,N.E., RECINIELLO,R.N., HU,J.P., & RORER,D.C. RADIATION DOSIMETRY OF THE PRESSURE VESSEL INTERNALS OF THE HIGH FLUX BEAM REACTOR.. United States.
HOLDEN,N.E., RECINIELLO,R.N., HU,J.P., and RORER,D.C. Sun . "RADIATION DOSIMETRY OF THE PRESSURE VESSEL INTERNALS OF THE HIGH FLUX BEAM REACTOR.". United States. https://www.osti.gov/servlets/purl/801700.
@article{osti_801700,
title = {RADIATION DOSIMETRY OF THE PRESSURE VESSEL INTERNALS OF THE HIGH FLUX BEAM REACTOR.},
author = {HOLDEN,N.E. and RECINIELLO,R.N. and HU,J.P. and RORER,D.C.},
abstractNote = {In preparation for the eventual decommissioning of the High Flux Beam Reactor after the permanent removal of its fuel elements from the Brookhaven National Laboratory, both measurements and calculations of the decay gamma-ray dose rate have been performed for the reactor pressure vessel and vessel internal structures which included the upper and lower thermal shields, the transition plate, and the control rod blades. The measurements were made using Red Perspex{trademark} polymethyl methacrylate high-level film dosimeters, a Radcal ''peanut'' ion chamber, and Eberline's high-range ion chamber. To compare with measured gamma-ray dose rate, the Monte Carlo MCNP code and geometric progressive Microshield code were used to model the gamma transport and dose buildup.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = {2002},
month = {8}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: