Title: RHIC ABORT KICKER WITH REDUCED COUPLING IMPEDANCE.

Abstract

Kicker magnets typically represent the most important contributors to the transverse impedance budget of accelerators and storage rings. Methods of reducing the impedance value of the SNS extraction kicker presently under construction and, in view of a future performance upgrade, that of the RHIC abort kicker have been thoroughly studied at this laboratory. In this paper, the investigation of a potential improvement from using ferrite different from the BNL standard CMD5005 is reported. Permeability measurements of several ferrite types have been performed. Measurements on two kicker magnets using CMD5005 and C2050 suggest that the impedance of a magnet without external resistive damping, such as the RHIC abort kicker, would benefit.

Authors:
;
Publication Date:
Research Org.:
Brookhaven National Lab., Upton, NY (US)
Sponsoring Org.:
USDOE Office of Energy Research (ER) (US)
OSTI Identifier:
798550
Report Number(s):
BNL-68953
R&D Project: AD003; KA0202011; TRN: US0204839
DOE Contract Number:  
AC02-98CH10886
Resource Type:
Conference
Resource Relation:
Conference: 2002 EUROPEAN PARTICLE ACCELERATOR CONFERENCE, PARIS (FR), 06/02/2002--06/07/2002; Other Information: PBD: 2 Jun 2002
Country of Publication:
United States
Language:
English
Subject:
43 PARTICLE ACCELERATORS; ACCELERATORS; IMPEDANCE; BROOKHAVEN RHIC

Citation Formats

HAHN,H., and DAVINO,D. RHIC ABORT KICKER WITH REDUCED COUPLING IMPEDANCE.. United States: N. p., 2002. Web.
HAHN,H., & DAVINO,D. RHIC ABORT KICKER WITH REDUCED COUPLING IMPEDANCE.. United States.
HAHN,H., and DAVINO,D. Sun . "RHIC ABORT KICKER WITH REDUCED COUPLING IMPEDANCE.". United States. https://www.osti.gov/servlets/purl/798550.
@article{osti_798550,
title = {RHIC ABORT KICKER WITH REDUCED COUPLING IMPEDANCE.},
author = {HAHN,H. and DAVINO,D.},
abstractNote = {Kicker magnets typically represent the most important contributors to the transverse impedance budget of accelerators and storage rings. Methods of reducing the impedance value of the SNS extraction kicker presently under construction and, in view of a future performance upgrade, that of the RHIC abort kicker have been thoroughly studied at this laboratory. In this paper, the investigation of a potential improvement from using ferrite different from the BNL standard CMD5005 is reported. Permeability measurements of several ferrite types have been performed. Measurements on two kicker magnets using CMD5005 and C2050 suggest that the impedance of a magnet without external resistive damping, such as the RHIC abort kicker, would benefit.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = {2002},
month = {6}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: