skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: 6430.1A Compliance Matrix for 241-SY-101 Surface Level Rise Remediation Project

Abstract

Tank 241-SY-101 (SY-101) has recently exhibited a steady waste surface level growth. A path forward to mitigate the SY-101 surface level growth issue has been developed. The project has been directed to install the necessary equipment to transfer 380-570m{sup 3} (100,000-150,000 gallons) of waste from SY-101 to SY-102 before the waste elevation reached the region of the tank where the transition from a double to a single shell tank occurs. The purpose of this document is to record the design attributes of the RAPID mitigation system which fulfill the requirements specified in DOE order 6430.1A as it relates to the 241-SY-101 RAPID Mitigation System.

Authors:
Publication Date:
Research Org.:
LMHC (US)
Sponsoring Org.:
ENVIRONMENTAL MANAGEMENT (US)
OSTI Identifier:
797751
Report Number(s):
RPP-4993, Rev.0
TRN: US0204985
DOE Contract Number:  
AC27-99RL14047
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 18 Aug 1999
Country of Publication:
United States
Language:
English
Subject:
12 MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; COMPLIANCE; DESIGN; MITIGATION; LEVELS; STORAGE FACILITIES; RADIOACTIVE WASTE STORAGE; WASTE RETRIEVAL; MASS TRANSFER

Citation Formats

ERHART, M.F. 6430.1A Compliance Matrix for 241-SY-101 Surface Level Rise Remediation Project. United States: N. p., 1999. Web. doi:10.2172/797751.
ERHART, M.F. 6430.1A Compliance Matrix for 241-SY-101 Surface Level Rise Remediation Project. United States. doi:10.2172/797751.
ERHART, M.F. Wed . "6430.1A Compliance Matrix for 241-SY-101 Surface Level Rise Remediation Project". United States. doi:10.2172/797751. https://www.osti.gov/servlets/purl/797751.
@article{osti_797751,
title = {6430.1A Compliance Matrix for 241-SY-101 Surface Level Rise Remediation Project},
author = {ERHART, M.F.},
abstractNote = {Tank 241-SY-101 (SY-101) has recently exhibited a steady waste surface level growth. A path forward to mitigate the SY-101 surface level growth issue has been developed. The project has been directed to install the necessary equipment to transfer 380-570m{sup 3} (100,000-150,000 gallons) of waste from SY-101 to SY-102 before the waste elevation reached the region of the tank where the transition from a double to a single shell tank occurs. The purpose of this document is to record the design attributes of the RAPID mitigation system which fulfill the requirements specified in DOE order 6430.1A as it relates to the 241-SY-101 RAPID Mitigation System.},
doi = {10.2172/797751},
journal = {},
number = ,
volume = ,
place = {United States},
year = {1999},
month = {8}
}