skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Final results of double-shell tank 241-AN-105 ultrasonic inspection

Abstract

This document presents the results and documentation of the nondestructive ultrasonic examination of tank 241-AN-105. A tank inspection supplier was retained to provide and use an ultrasonic examination system (equipment, procedures, and inspectors) to scan a limited area of double-shell tank 241-AN-105 primary tank wall primary knuckle, and secondary tank bottom. The inspection found some indication of general and local wall thinning with no cracks detected.

Authors:
Publication Date:
Research Org.:
LMHC (US)
Sponsoring Org.:
ENVIRONMENTAL MANAGEMENT (US)
OSTI Identifier:
797735
Report Number(s):
HNF-4816, Rev.0
TRN: US0204926
DOE Contract Number:  
AC06-96RL13200
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 23 Aug 1999
Country of Publication:
United States
Language:
English
Subject:
12 MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; STORAGE FACILITIES; ULTRASONIC TESTING; RADIOACTIVE WASTE STORAGE; IN-SERVICE INSPECTION; CORROSION

Citation Formats

JENSEN, C.E. Final results of double-shell tank 241-AN-105 ultrasonic inspection. United States: N. p., 1999. Web. doi:10.2172/797735.
JENSEN, C.E. Final results of double-shell tank 241-AN-105 ultrasonic inspection. United States. doi:10.2172/797735.
JENSEN, C.E. Mon . "Final results of double-shell tank 241-AN-105 ultrasonic inspection". United States. doi:10.2172/797735. https://www.osti.gov/servlets/purl/797735.
@article{osti_797735,
title = {Final results of double-shell tank 241-AN-105 ultrasonic inspection},
author = {JENSEN, C.E.},
abstractNote = {This document presents the results and documentation of the nondestructive ultrasonic examination of tank 241-AN-105. A tank inspection supplier was retained to provide and use an ultrasonic examination system (equipment, procedures, and inspectors) to scan a limited area of double-shell tank 241-AN-105 primary tank wall primary knuckle, and secondary tank bottom. The inspection found some indication of general and local wall thinning with no cracks detected.},
doi = {10.2172/797735},
journal = {},
number = ,
volume = ,
place = {United States},
year = {1999},
month = {8}
}