IMPACT OF DUCT LEAKAGE PRESSURES ON THE SHAPE OF THE DELTA Q CURVE.
The question of whether and to what extent information on the pressures driving duct leaks can be extracted from the data taken during the Delta Q test for duct leakage is investigated. Curves of Delta Q vs. house pressure are generated for sets of cases where the supply and return leakage rates to/from outside are held constant while the leakage pressures are varied. It is found that the Delta Q curve takes on two qualitatively different shapes, one for leakage pressures within the range of house pressures used in the Delta Q test (i.e., -25 Pa to +25 Pa) and the other for leakage pressures well outside this range. These effects are seen in experimental data taken with leakage at known pressures. However, extracting the signal of the leakage pressure from the surrounding noise caused by random measurement variation is likely to be a difficult problem in many cases.
- Research Organization:
- Brookhaven National Lab. (BNL), Upton, NY (United States)
- Sponsoring Organization:
- USDOE Office of Energy Research (ER) (US)
- DOE Contract Number:
- AC02-98CH10886
- OSTI ID:
- 793051
- Report Number(s):
- BNL-69049; R&D Project: EST112NEDA; EC0904000; TRN: US0200896
- Resource Relation:
- Other Information: PBD: 1 Feb 2002
- Country of Publication:
- United States
- Language:
- English
Similar Records
LABORATORY EVALUATION OF THE DELTA Q TEST FOR DUCT LEAKAGE
Building cavities used as ducts: Air leakage characteristics and impacts in light commercial buildings