Results of hybrid photodiode irradiation by 200 MeV protons
Hybrid Photodiodes (HPD, [1]) will be used as the photodetector for the Compact Muon Solenoid (CMS) Hadron Calorimeter (HCAL) readout [2]. The HPDs are required to operate in a high radiation environment, where the HCAL detector will receive a total ionizing dose of about 330 rads and a fluence of 4 x 10{sup 11} n/cm{sup 2} over a 10 year running period [3]. Effects of HPD irradiation by low energy neutrons were studied and reported previously [1]. In these studies, high energy protons are used to study possible effects of single event burnout [4], since high energy protons are more likely to induce large energy transfer within the HPD silicon. The HPDs were irradiated by 200 MeV protons at the Indiana University Cyclotron Facility [IUCF, 5]. The results of the study are presented.
- Research Organization:
- Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
- Sponsoring Organization:
- USDOE Office of Energy Research (ER) (US)
- DOE Contract Number:
- AC02-76CH03000
- OSTI ID:
- 789212
- Report Number(s):
- FERMILAB-TM-2162; TRN: US0111340
- Resource Relation:
- Other Information: PBD: 3 Dec 2001
- Country of Publication:
- United States
- Language:
- English
Similar Records
Test of the DEP hybrid photodiode in 5 Tesla Magnet