skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: ENRAF annulus leak detector development test

Technical Report ·
DOI:https://doi.org/10.2172/782315· OSTI ID:782315

ENRAF 854 ATG level detectors are normally used for measuring and tracking waste levels in the Hanford waste tanks. Since instrument technicians and operators are familiar with these gauges, it has been suggested that ENRAF 854's be used to alleviate problems with the existing annulus leak detector devices. The purpose of this test is to determine the following: (1) The liquid level at which the gauge will report a change in level, given the displacer initially resting on the bottom of a container; and (2) Whether the high alarm level can be set at 0.25 inch above the bottom of the container. This test and its results will be applicable to ENRAF 854 ATG level detectors used as annulus leak detectors.

Research Organization:
Hanford Site (HNF), Richland, WA (United States)
Sponsoring Organization:
US DOE Office of Environmental Management (US)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
782315
Report Number(s):
HNF-4033-REV0; TRN: US0203125
Resource Relation:
Other Information: PBD: 20 May 1999
Country of Publication:
United States
Language:
English