skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Hanford Tank Farms Vadose Zone, Addendum to the T Tank Farm Report

Technical Report ·
DOI:https://doi.org/10.2172/765880· OSTI ID:765880

This addendum to the T Tank Farm Report (GJO-99-101-TARA, GJO-HAN-27) published in September 1999 incorporates the results of high-rate and repeat logging activities along with shape factor analysis of the logging incorporates the results of high-rate and repeat logging activities along with shape factor analysis of the logging data. A high-rate logging system was developed and deployed in the T Tank Farm to measure cesium-137 concentration levels in high gamma flux zones where the spectral gamma logging system was unable to collect usable data because of high dead times and detector saturation. This report presents additional data and revised visualizations of subsurface contaminant distribution in the T Tank Farm at the DOE Hanford Site in the state of Washington.

Research Organization:
U.S. Department of Energy Grand Junction Office (US)
Sponsoring Organization:
USDOE; USDOE Office of Environmental Management (EM) (US)
DOE Contract Number:
AC13-96GJ87335
OSTI ID:
765880
Report Number(s):
GJO-99-101-TARA; GJO-HAN-27; TRN: US0100284
Resource Relation:
Other Information: PBD: 1 Jul 2000
Country of Publication:
United States
Language:
English