Title: Development of X-ray tracer diagnostics for radiatively-driven ablator experiments [annual report FY1998]

Technical Report ·
DOI:https://doi.org/10.2172/765022· OSTI ID:765022

This report covers fiscal year 1998 of our ongoing project to develop tracer X-ray spectroscopic diagnostics for hohlraum environments. This effort focused on an experimental campaign carried out at OMEGA on 25--27 August 1998. This phase of the project heavily emphasized experimental design, diagnostic development, and target fabrication, as well as building up numerical models for the experiments. The spectral diagnostic under development involves using two thin (few 1000 {angstrom}) mid-Z tracers in two witness plates mounted on the side of a hohlraum with the tracers' K{sub a} absorption features seen against an X-ray backlighter. The absorption data are used to sample the time-dependent, localized properties of each witness plate as a radiation wave ablates it. The experiments represented the first application of this diagnostic, in this case to side-by-side doped and undoped plastic to investigate the effects of capsule ablator dopants.

Research Organization:
Prism Computational Sciences, Inc., Madison, WI (US)
Sponsoring Organization:
USDOE; USDOE Office of Energy Research (ER) (US)
DOE Contract Number:
FG03-99SF21779
OSTI ID:
765022
Report Number(s):
PCS-R-003; TRN: US0103072
Resource Relation:
Other Information: PBD: 1 May 1999
Country of Publication:
United States