Title: Irradiation of Nd-Fe-B permanent magnets with APS bending magnet x-rays and {sup 60}Co {gamma}-rays

Abstract

The Advanced Photon Source (APS), as well as other third-generation synchrotron light sources, uses permanent magnets in the insertion devices to produce x-rays for scientific research. When placed in a high-energy storage ring, these permanent magnets are subjected to irradiation from synchrotron radiation, high-energy bremsstrahlung, and bremsstrahlung-produced photoneutrons. Previous investigations have exhibited varying degrees of degradation in the intensity of magnetization of these magnets due to irradiation from electron beams, {sup 60}Co {gamma}rays, and high-energy neutrons. The APS specifically uses Nd-Fe-B permanent magnets in their insertion devices. Although no detectable radiation-induced demagnetization has been observed in the APS insertion devices so far, partial demagnetization has been observed in at least one insertion device at the European Synchrotron Radiation Facility (ESRF), where Nd-Fe-B permanent magnets are also used.

Authors:
; ;
Publication Date:
Research Org.:
Argonne National Lab., IL (US)
Sponsoring Org.:
US Department of Energy (US)
OSTI Identifier:
764212
Report Number(s):
LS-288
TRN: US0004928
DOE Contract Number:  
W-31109-ENG-38
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 8 Sep 2000
Country of Publication:
United States
Language:
English
Subject:
43 PARTICLE ACCELERATORS; ADVANCED PHOTON SOURCE; BREMSSTRAHLUNG; DEMAGNETIZATION; ELECTRON BEAMS; IRRADIATION; LIGHT SOURCES; MAGNETIZATION; PERMANENT MAGNETS; PHOTONEUTRONS; STORAGE RINGS; SYNCHROTRON RADIATION; SYNCHROTRONS; NEODYMIUM BORIDES; IRON BORIDES; GAMMA RADIATION

Citation Formats

Alderman, J, Job, P K, and Puhl, J. Irradiation of Nd-Fe-B permanent magnets with APS bending magnet x-rays and {sup 60}Co {gamma}-rays. United States: N. p., 2000. Web. doi:10.2172/764212.
Alderman, J, Job, P K, & Puhl, J. Irradiation of Nd-Fe-B permanent magnets with APS bending magnet x-rays and {sup 60}Co {gamma}-rays. United States. doi:10.2172/764212.
Alderman, J, Job, P K, and Puhl, J. Fri . "Irradiation of Nd-Fe-B permanent magnets with APS bending magnet x-rays and {sup 60}Co {gamma}-rays". United States. doi:10.2172/764212. https://www.osti.gov/servlets/purl/764212.
@article{osti_764212,
title = {Irradiation of Nd-Fe-B permanent magnets with APS bending magnet x-rays and {sup 60}Co {gamma}-rays},
author = {Alderman, J and Job, P K and Puhl, J},
abstractNote = {The Advanced Photon Source (APS), as well as other third-generation synchrotron light sources, uses permanent magnets in the insertion devices to produce x-rays for scientific research. When placed in a high-energy storage ring, these permanent magnets are subjected to irradiation from synchrotron radiation, high-energy bremsstrahlung, and bremsstrahlung-produced photoneutrons. Previous investigations have exhibited varying degrees of degradation in the intensity of magnetization of these magnets due to irradiation from electron beams, {sup 60}Co {gamma}rays, and high-energy neutrons. The APS specifically uses Nd-Fe-B permanent magnets in their insertion devices. Although no detectable radiation-induced demagnetization has been observed in the APS insertion devices so far, partial demagnetization has been observed in at least one insertion device at the European Synchrotron Radiation Facility (ESRF), where Nd-Fe-B permanent magnets are also used.},
doi = {10.2172/764212},
journal = {},
number = ,
volume = ,
place = {United States},
year = {2000},
month = {9}
}

Technical Report:

Save / Share: