skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: The effect of noise on transverse emittance growth in the Tevatron

Technical Report ·
DOI:https://doi.org/10.2172/760837· OSTI ID:760837

Emittance growth due to noise from a transverse beam feedback system are discussed. A theory for calculating emittance growth rate as a function of the feedback system's measured open loop transfer function is derived. A simple feedback system was installed, measured, and tested in the Fermilab Tevatron, and the emittance growth rate results agree very closely with the theory.

Research Organization:
Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
Sponsoring Organization:
USDOE Office of Energy Research (ER) (US)
DOE Contract Number:
AC02-76CH03000
OSTI ID:
760837
Report Number(s):
FERMILAB-TM-2121; TRN: US0004522
Resource Relation:
Other Information: PBD: 28 Aug 2000
Country of Publication:
United States
Language:
English