Abstract

Preliminary Monte Carlo simulations have demonstrated that passive Nuclear Materials Identification System (NMIS) measurements can be used to determine the mass of Pu in AT400-R containers with measurement times as short as a few minutes. The sensitivity of the proposed detectors to gamma rays should enhance this measurement method because the gamma rays from fission, induced or spontaneous, escape this container more easily than neutrons. In these calculations, the container contained two Pu spheres with mass varying between 0.5 and 2 Kg with {approximately}6 wt% {sup 240 }Pu.

Authors:
Publication Date:
Research Org.:
Oak Ridge Y-12 Plant, TN (US)
Sponsoring Org.:
USDOE Office of Defense Programs (DP) (US)
OSTI Identifier:
757200
Report Number(s):
Y/LB-16,027
TRN: US0003374
DOE Contract Number:  
AC05-84OR21400
Resource Type:
Conference
Resource Relation:
Conference: Institute of Nuclear Materials Management, New Orleans, LA (US), 07/16/2000--07/20/2000; Other Information: PBD: 30 May 2000
Country of Publication:
United States
Language:
English
Subject:
98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL PROTECTION; 46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; PLUTONIUM; NUCLEAR MATERIALS MANAGEMENT; CONTAINERS; RADIOISOTOPE SCANNING; GAMMA DETECTION; MONTE CARLO METHOD; RADIOISOTOPE SCANNERS; COMPUTERIZED SIMULATION

Citation Formats

T.E. Valentine, L.G. Chiang, J.T. Mihalczo. Monte Carlo evaluation of passive NMIS for assay of plutonium in shielded containers. United States: N. p., 2000. Web.
T.E. Valentine, L.G. Chiang, J.T. Mihalczo. Monte Carlo evaluation of passive NMIS for assay of plutonium in shielded containers. United States.
T.E. Valentine, L.G. Chiang, J.T. Mihalczo. Tue . "Monte Carlo evaluation of passive NMIS for assay of plutonium in shielded containers". United States. https://www.osti.gov/servlets/purl/757200.
@article{osti_757200,
title = {Monte Carlo evaluation of passive NMIS for assay of plutonium in shielded containers},
author = {T.E. Valentine, L.G. Chiang, J.T. Mihalczo},
abstractNote = {Preliminary Monte Carlo simulations have demonstrated that passive Nuclear Materials Identification System (NMIS) measurements can be used to determine the mass of Pu in AT400-R containers with measurement times as short as a few minutes. The sensitivity of the proposed detectors to gamma rays should enhance this measurement method because the gamma rays from fission, induced or spontaneous, escape this container more easily than neutrons. In these calculations, the container contained two Pu spheres with mass varying between 0.5 and 2 Kg with {approximately}6 wt% {sup 240 }Pu.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = {2000},
month = {5}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: