Title: Selected component failure rate values from fusion safety assessment tasks

Abstract

This report is a compilation of component failure rate and repair rate values that can be used in magnetic fusion safety assessment tasks. Several safety systems are examined, such as gas cleanup systems and plasma shutdown systems. Vacuum system component reliability values, including large vacuum chambers, have been reviewed. Values for water cooling system components have also been reported here. The report concludes with the examination of some equipment important to personnel safety, atmospheres, combustible gases, and airborne releases of radioactivity. These data should be useful to system designers to calculate scoping values for the availability and repair intervals for their systems, and for probabilistic safety or risk analysts to assess fusion systems for safety of the public and the workers.

Authors:
Publication Date:
Research Org.:
Idaho National Engineering and Environmental Lab., Idaho Falls, ID (US)
Sponsoring Org.:
USDOE Office of Energy Research (ER) (US)
OSTI Identifier:
752571
Report Number(s):
INEEL/EXT-98-00892
TRN: US0001361
DOE Contract Number:  
AC07-94ID13223
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 1 Sep 1998
Country of Publication:
United States
Language:
English
Subject:
70 PLASMA PHYSICS AND FUSION TECHNOLOGY; MAGNETIC CONFINEMENT; THERMONUCLEAR DEVICES; SAFETY ANALYSIS; ENGINEERED SAFETY SYSTEMS; FAILURES; VACUUM SYSTEMS; REPAIR; THERMONUCLEAR REACTOR COOLING SYSTEMS; OCCUPATIONAL SAFETY; RISK ASSESSMENT; FAILURE RATE; REPAIR RATE; MAGNETIC FUSION SAFETY; PLASMA SHUTDOWN; VACUUM CHAMBERS; OXYGEN DEFICIENCY; TOXIC GAS; COMBUSTIBLE GASES; AIRBORNE RELEASES; SCOPING VALUES; FUSION SYSTEMS

Citation Formats

Cadwallader, L C. Selected component failure rate values from fusion safety assessment tasks. United States: N. p., 1998. Web. doi:10.2172/752571.
Cadwallader, L C. Selected component failure rate values from fusion safety assessment tasks. United States. doi:10.2172/752571.
Cadwallader, L C. Tue . "Selected component failure rate values from fusion safety assessment tasks". United States. doi:10.2172/752571. https://www.osti.gov/servlets/purl/752571.
@article{osti_752571,
title = {Selected component failure rate values from fusion safety assessment tasks},
author = {Cadwallader, L C},
abstractNote = {This report is a compilation of component failure rate and repair rate values that can be used in magnetic fusion safety assessment tasks. Several safety systems are examined, such as gas cleanup systems and plasma shutdown systems. Vacuum system component reliability values, including large vacuum chambers, have been reviewed. Values for water cooling system components have also been reported here. The report concludes with the examination of some equipment important to personnel safety, atmospheres, combustible gases, and airborne releases of radioactivity. These data should be useful to system designers to calculate scoping values for the availability and repair intervals for their systems, and for probabilistic safety or risk analysts to assess fusion systems for safety of the public and the workers.},
doi = {10.2172/752571},
journal = {},
number = ,
volume = ,
place = {United States},
year = {1998},
month = {9}
}