skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Maintaining the closed magnetic-field-line topology of a field-reversed configuration (FRC) with the addition of static transverse magnetic fields

Abstract

The effects on magnetic-field-line structure of adding various static transverse magnetic fields to a Solovev-equilibrium field-reversed configuration is examined. It is shown that adding fields that are anti-symmetric about the axial mid-plane maintains the closed field-line structure, while adding fields with planar or helical symmetry opens the field structure. Anti-symmetric modes also introduce pronounced shear.

Authors:
;
Publication Date:
Research Org.:
Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States)
Sponsoring Org.:
USDOE Office of Energy Research (ER) (US)
OSTI Identifier:
750253
Report Number(s):
PPPL-3418
TRN: US0000740
DOE Contract Number:  
AC02-76CH03073
Resource Type:
Technical Report
Resource Relation:
Other Information: PBD: 13 Jan 2000
Country of Publication:
United States
Language:
English
Subject:
70 PLASMA PHYSICS AND FUSION; MAGNETIC FIELD REVERSAL; MAGNETIC FIELDS; SHEAR; THERMONUCLEAR DEVICES

Citation Formats

Cohen, S A, and Milroy, R D. Maintaining the closed magnetic-field-line topology of a field-reversed configuration (FRC) with the addition of static transverse magnetic fields. United States: N. p., 2000. Web. doi:10.2172/750253.
Cohen, S A, & Milroy, R D. Maintaining the closed magnetic-field-line topology of a field-reversed configuration (FRC) with the addition of static transverse magnetic fields. United States. https://doi.org/10.2172/750253
Cohen, S A, and Milroy, R D. Thu . "Maintaining the closed magnetic-field-line topology of a field-reversed configuration (FRC) with the addition of static transverse magnetic fields". United States. https://doi.org/10.2172/750253. https://www.osti.gov/servlets/purl/750253.
@article{osti_750253,
title = {Maintaining the closed magnetic-field-line topology of a field-reversed configuration (FRC) with the addition of static transverse magnetic fields},
author = {Cohen, S A and Milroy, R D},
abstractNote = {The effects on magnetic-field-line structure of adding various static transverse magnetic fields to a Solovev-equilibrium field-reversed configuration is examined. It is shown that adding fields that are anti-symmetric about the axial mid-plane maintains the closed field-line structure, while adding fields with planar or helical symmetry opens the field structure. Anti-symmetric modes also introduce pronounced shear.},
doi = {10.2172/750253},
url = {https://www.osti.gov/biblio/750253}, journal = {},
number = ,
volume = ,
place = {United States},
year = {Thu Jan 13 00:00:00 EST 2000},
month = {Thu Jan 13 00:00:00 EST 2000}
}