Title: Self-healing of defects in CaO coatings on V-5%Cr-5%Ti in liquid lithium

Abstract

In-situ electrical resistance of CaO coatings produced on V-5%Cr-5%Ti by exposure of the alloy to liquid Li that contained 0.5-85 wt % dissolved Ca was measured as a function of time at temperatures between 250 and 600{degrees}C. Examination of the specimens after cooling to room temperature revealed no spallation, but homogeneous crazing cracks were present in the CaO coating. Additional tests to investigate the in-situ self-healing behavior of the cracks indicated that rapid healing occurred at >360{degrees}C.

Authors:
;
Publication Date:
Research Org.:
Argonne National Lab. (ANL), Argonne, IL (United States)
Sponsoring Org.:
USDOE, Washington, DC (United States)
OSTI Identifier:
74182
Report Number(s):
ANL/ET/CP-84955; CONF-950518-10
ON: DE95013468
DOE Contract Number:  
W-31-109-ENG-38
Resource Type:
Conference
Resource Relation:
Conference: 187. meeting of the Electrochemical Society, Reno, NV (United States), 21-26 May 1995; Other Information: PBD: Nov 1994
Country of Publication:
United States
Language:
English
Subject:
70 PLASMA PHYSICS AND FUSION; 36 MATERIALS SCIENCE; CALCIUM OXIDES; DEFECTS; CORROSION RESISTANCE; TITANIUM BASE ALLOYS; PROTECTIVE COATINGS; VANADIUM ALLOYS; CHROMIUM ALLOYS; CRACKS; LITHIUM; LIQUID METALS; THERMAL CYCLING

Citation Formats

Park, J H, and Kassner, T F. Self-healing of defects in CaO coatings on V-5%Cr-5%Ti in liquid lithium. United States: N. p., 1994. Web.
Park, J H, & Kassner, T F. Self-healing of defects in CaO coatings on V-5%Cr-5%Ti in liquid lithium. United States.
Park, J H, and Kassner, T F. 1994. "Self-healing of defects in CaO coatings on V-5%Cr-5%Ti in liquid lithium". United States. https://www.osti.gov/servlets/purl/74182.
@article{osti_74182,
title = {Self-healing of defects in CaO coatings on V-5%Cr-5%Ti in liquid lithium},
author = {Park, J H and Kassner, T F},
abstractNote = {In-situ electrical resistance of CaO coatings produced on V-5%Cr-5%Ti by exposure of the alloy to liquid Li that contained 0.5-85 wt % dissolved Ca was measured as a function of time at temperatures between 250 and 600{degrees}C. Examination of the specimens after cooling to room temperature revealed no spallation, but homogeneous crazing cracks were present in the CaO coating. Additional tests to investigate the in-situ self-healing behavior of the cracks indicated that rapid healing occurred at >360{degrees}C.},
doi = {},
url = {https://www.osti.gov/biblio/74182}, journal = {},
number = ,
volume = ,
place = {United States},
year = {1994},
month = {11}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: