Title: Thermoelastic/plastic analysis of waste-container sleeve: IV. Air gap influence on hole closure. Technical memorandum report (RSI-0019)

Technical Report ·
DOI:https://doi.org/10.2172/7320384· OSTI ID:7320384

A thermoelastic/plastic finite element analysis of the influence of an air-gap on hole closure about a waste-container/sleeve assembly emplaced in a typical repository room (SALT/4T Model) indicates that hole closure would be of the order of hundredths of an inch. Acceptable air-gap width is thus governed by the hole size required for emplacement efficiency. A refined mesh analysis and laboratory testing is suggested in order to further explore the possibility of eliminating the engineering necessity of the sleeve.

Research Organization:
RE/SPEC, Inc., Rapid City, SD (USA)
DOE Contract Number:
W-7405-ENG-26
OSTI ID:
7320384
Report Number(s):
ORNL/SUB-4269/3; TRN: 77-015618
Country of Publication:
United States
Language:
English