Title: Mark I 1/5-scale boiling water reactor pressure suppression experiment summary of effects due to vent line orifice variations: air test series

Abstract

Twenty-seven air tests have been completed in the /sup 1///sub 5/-scale Mark I test facility. The observed effects of vent line orifice variations on the hydrodynamic vertical load function (HVLF) are presented. The conditions for standard tests, to which the orifice variation tests are compared, are defined and discussed. These tests used the ''standard'' or 9.5 inch orifices in the 90/sup 0/ sector vent lines.

Authors:
; ; ;
Publication Date:
Research Org.:
California Univ., Livermore (USA). Lawrence Livermore Lab.
Sponsoring Org.:
US Energy Research and Development Administration (ERDA)
OSTI Identifier:
7317988
Report Number(s):
UCID-17539
TRN: 77-015713
DOE Contract Number:  
W-7405-ENG-48
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; BWR TYPE REACTORS; CONTAINMENT SYSTEMS; HYDRODYNAMICS; PERFORMANCE TESTING; CONFIGURATION; ORIFICES; PIPELINES; PRESSURE GRADIENTS; CONTAINMENT; ENGINEERED SAFETY SYSTEMS; FLUID MECHANICS; MECHANICS; OPENINGS; REACTORS; TESTING; WATER COOLED REACTORS; WATER MODERATED REACTORS; 210100* - Power Reactors, Nonbreeding, Light-Water Moderated, Boiling Water Cooled

Citation Formats

McCauley, E. W., Lai, W., Meier, J., and Stein, W. Mark I 1/5-scale boiling water reactor pressure suppression experiment summary of effects due to vent line orifice variations: air test series. United States: N. p., 1977. Web. doi:10.2172/7317988.
McCauley, E. W., Lai, W., Meier, J., & Stein, W. Mark I 1/5-scale boiling water reactor pressure suppression experiment summary of effects due to vent line orifice variations: air test series. United States. https://doi.org/10.2172/7317988
McCauley, E. W., Lai, W., Meier, J., and Stein, W. Thu . "Mark I 1/5-scale boiling water reactor pressure suppression experiment summary of effects due to vent line orifice variations: air test series". United States. https://doi.org/10.2172/7317988. https://www.osti.gov/servlets/purl/7317988.
@article{osti_7317988,
title = {Mark I 1/5-scale boiling water reactor pressure suppression experiment summary of effects due to vent line orifice variations: air test series},
author = {McCauley, E. W. and Lai, W. and Meier, J. and Stein, W.},
abstractNote = {Twenty-seven air tests have been completed in the /sup 1///sub 5/-scale Mark I test facility. The observed effects of vent line orifice variations on the hydrodynamic vertical load function (HVLF) are presented. The conditions for standard tests, to which the orifice variation tests are compared, are defined and discussed. These tests used the ''standard'' or 9.5 inch orifices in the 90/sup 0/ sector vent lines.},
doi = {10.2172/7317988},
url = {https://www.osti.gov/biblio/7317988}, journal = {},
number = ,
volume = ,
place = {United States},
year = {1977},
month = {7}
}