skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: General Electric Company analytical model for loss-of-coolant analysis in accordance with 10CFR50 appendix K, amendment No. 1: calculation of low-flow film-boiling heat transfer for BWR LOCA analysis

Abstract

A model has been developed to calculate the heat transfer coefficient under low flow film or pool boiling conditions in the BWR geometry. The model includes the heat transferred by convection due to the vapor boundary layer and that transferred by radiation between the high temperature surface and the liquid. The model is verified against a range of single rod and full-scale rod bundle data. These data confirm the applicability of the model for a range of conditions postulated to occur during the BWR loss-of-coolant accident.

Authors:
; ; ;
Publication Date:
Research Org.:
General Electric Co., San Jose, CA (USA). Boiling Water Reactor Systems Dept.
OSTI Identifier:
7311718
Report Number(s):
NEDO-20566-1
TRN: 77-011332
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
22 GENERAL STUDIES OF NUCLEAR REACTORS; 21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; BWR TYPE REACTORS; LOSS OF COOLANT; MATHEMATICAL MODELS; FILM BOILING; HEAT TRANSFER; ACCIDENTS; BOILING; ENERGY TRANSFER; PHASE TRANSFORMATIONS; REACTOR ACCIDENTS; REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS; 220900* - Nuclear Reactor Technology- Reactor Safety; 210100 - Power Reactors, Nonbreeding, Light-Water Moderated, Boiling Water Cooled

Citation Formats

Leonard, J.E., Sun, K.H., Anderson, J.G.M., and Dix, G.E. General Electric Company analytical model for loss-of-coolant analysis in accordance with 10CFR50 appendix K, amendment No. 1: calculation of low-flow film-boiling heat transfer for BWR LOCA analysis. United States: N. p., 1977. Web.
Leonard, J.E., Sun, K.H., Anderson, J.G.M., & Dix, G.E. General Electric Company analytical model for loss-of-coolant analysis in accordance with 10CFR50 appendix K, amendment No. 1: calculation of low-flow film-boiling heat transfer for BWR LOCA analysis. United States.
Leonard, J.E., Sun, K.H., Anderson, J.G.M., and Dix, G.E. Sat . "General Electric Company analytical model for loss-of-coolant analysis in accordance with 10CFR50 appendix K, amendment No. 1: calculation of low-flow film-boiling heat transfer for BWR LOCA analysis". United States.
@article{osti_7311718,
title = {General Electric Company analytical model for loss-of-coolant analysis in accordance with 10CFR50 appendix K, amendment No. 1: calculation of low-flow film-boiling heat transfer for BWR LOCA analysis},
author = {Leonard, J.E. and Sun, K.H. and Anderson, J.G.M. and Dix, G.E.},
abstractNote = {A model has been developed to calculate the heat transfer coefficient under low flow film or pool boiling conditions in the BWR geometry. The model includes the heat transferred by convection due to the vapor boundary layer and that transferred by radiation between the high temperature surface and the liquid. The model is verified against a range of single rod and full-scale rod bundle data. These data confirm the applicability of the model for a range of conditions postulated to occur during the BWR loss-of-coolant accident.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = {1977},
month = {1}
}

Technical Report:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that may hold this item. Keep in mind that many technical reports are not cataloged in WorldCat.