Effect of turbulence on orifice meter performance
- Novacor Research Technology Corp., Calgary, Alberta (Canada)
Mean and turbulent velocity profiles downstream of a 19-tube bundle are presented. Experiments have been carried out in 101.6-mm-dia. piping configuration at prevalent atmospheric conditions with air as the fluid. The two cases considered are: one with the tube bundle placed in good flow conditions and the other with the tube bundle used as a sliding vane downstream of a single 90-deg elbow. In both cases, for various positions of the tube bundle with respect to an orifice plate, the discharge coefficient for the orifice plate has been compared to a baseline value. The results indicate that it is possible to correlate the deviations in the discharge coefficient to the mean and turbulent velocity field upstream of the orifice.
- OSTI ID:
- 7235161
- Journal Information:
- Journal of Offshore Mechanics and Arctic Engineering; (United States), Vol. 116:2; ISSN 0892-7219
- Country of Publication:
- United States
- Language:
- English
Similar Records
Flow conditioner tests for three orifice flowmeter sizes. Technical note
Beta ratio, axisymmetric flow distortion, and swirl effects upon orifice flow meters
Related Subjects
03 NATURAL GAS
02 PETROLEUM
FLOWMETERS
ORIFICES
PERFORMANCE
TURBULENT FLOW
STANDARDS
PIPELINES
FLUID FLOW
MEASURING INSTRUMENTS
METERS
OPENINGS
420400* - Engineering- Heat Transfer & Fluid Flow
420205 - Engineering- Transport & Storage Facilities- (1980-)
032000 - Natural Gas- Transport
Handling
& Storage
022000 - Petroleum- Transport
Handling
& Storage