Title: Survey of flue gas desulfurization systems: Hawthorn Station, Kansas City Power and Light Co. Final report

Technical Report ·
OSTI ID:7138762

Results are given of a survey of the flue gas desulfurization (FGD) systems at Kansas City Power and Light Co.'s Hawthorn Power Station. The FGD systems on Hawthorn boilers 3 and 4 were designed to operate by injection of dry limestone in the boiler's furnace, followed by tail gas scrubbing. Because of tube plugging in boiler 4 the mode of operation of the FGD system on that boiler was modified: ground limestone is now introduced into the flue gas near the gas inlet to the scrubber tower. (GRA)

Research Organization:
PEDCO-Environmental Specialists, Inc., Cincinnati, Ohio (USA)
DOE Contract Number:
EPA-68-02-1321
OSTI ID:
7138762
Report Number(s):
PB-246629
Resource Relation:
Other Information: See also PB--244401
Country of Publication:
United States