Capability evaluation of a sinogram error detection and correction method in computed tomography
Conference
·
· IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States)
OSTI ID:7136222
- California Univ., Los Angeles, CA (United States). School of Medicine
In this paper an iterative method for detecting and correcting errors in sinograms is described and its capability evaluated. The method is based on the use of a reconstruction-reprojection procedure to check the consistency of a sinogram. Adjustments of the sinogram are made iteratively to satisfy gradually the consistency requirement. The effectiveness of the method for detecting and correcting errors due to scanner detector problems is demonstrated with computer simulated data and with real data from positron emission tomography. The potential usefulness of the method for quality control of scanners is discussed.
- OSTI ID:
- 7136222
- Report Number(s):
- CONF-911106-; CODEN: IETNAE
- Journal Information:
- IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States), Vol. 39:4; Conference: 1991 Institute of Electrical and Electronic Engineers (IEEE) nuclear science symposium and medical imaging conference, Santa Fe, NM (United States), 2-9 Nov 1991; ISSN 0018-9499
- Country of Publication:
- United States
- Language:
- English
Similar Records
4D numerical observer for lesion detection in respiratory-gated PET
Iterative Dense Correspondence Correction Through Bundle Adjustment Feedback-Based Error Detection
Iterative metal artifact reduction for x-ray computed tomography using unmatched projector/backprojector pairs
Journal Article
·
Wed Oct 15 00:00:00 EDT 2014
· Medical Physics
·
OSTI ID:7136222
+4 more
Iterative Dense Correspondence Correction Through Bundle Adjustment Feedback-Based Error Detection
Conference
·
Mon Nov 23 00:00:00 EST 2009
·
OSTI ID:7136222
+1 more
Iterative metal artifact reduction for x-ray computed tomography using unmatched projector/backprojector pairs
Journal Article
·
Wed Jun 15 00:00:00 EDT 2016
· Medical Physics
·
OSTI ID:7136222
+3 more
Related Subjects
62 RADIOLOGY AND NUCLEAR MEDICINE
61 RADIATION PROTECTION AND DOSIMETRY
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
99 GENERAL AND MISCELLANEOUS//MATHEMATICS, COMPUTING, AND INFORMATION SCIENCE
COMPUTERIZED TOMOGRAPHY
EVALUATION
IMAGE PROCESSING
EFFICIENCY
QUALITY CONTROL
IMAGE SCANNERS
COMPUTERIZED SIMULATION
ERRORS
DATA ANALYSIS
ITERATIVE METHODS
POSITRON COMPUTED TOMOGRAPHY
CALCULATION METHODS
CONTROL
DIAGNOSTIC TECHNIQUES
EMISSION COMPUTED TOMOGRAPHY
PROCESSING
SIMULATION
TOMOGRAPHY
550602* - Medicine- External Radiation in Diagnostics- (1980-)
560101 - Biomedical Sciences
Applied Studies- Radiation Effects- Dosimetry & Monitoring- (1992-)
440100 - Radiation Instrumentation
990200 - Mathematics & Computers
61 RADIATION PROTECTION AND DOSIMETRY
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY
99 GENERAL AND MISCELLANEOUS//MATHEMATICS, COMPUTING, AND INFORMATION SCIENCE
COMPUTERIZED TOMOGRAPHY
EVALUATION
IMAGE PROCESSING
EFFICIENCY
QUALITY CONTROL
IMAGE SCANNERS
COMPUTERIZED SIMULATION
ERRORS
DATA ANALYSIS
ITERATIVE METHODS
POSITRON COMPUTED TOMOGRAPHY
CALCULATION METHODS
CONTROL
DIAGNOSTIC TECHNIQUES
EMISSION COMPUTED TOMOGRAPHY
PROCESSING
SIMULATION
TOMOGRAPHY
550602* - Medicine- External Radiation in Diagnostics- (1980-)
560101 - Biomedical Sciences
Applied Studies- Radiation Effects- Dosimetry & Monitoring- (1992-)
440100 - Radiation Instrumentation
990200 - Mathematics & Computers