The application of position-sensitive phoswich detectors for low-mass fragment detection in an array environment
Conference
·
OSTI ID:7057982
Large solid angle position-sensitive phoswich detectors have been constructed to replace smaller units in an array for detecting medium mass fragments (Z less than or equal to 15) in nuclear experiments. The position information was obtained from a time analysis method. 5 refs., 9 figs.
- Research Organization:
- Lawrence Berkeley Lab., CA (USA)
- DOE Contract Number:
- AC03-76SF00098
- OSTI ID:
- 7057982
- Report Number(s):
- LBL-24529; CONF-870410-41; ON: DE89002670; TRN: 88-037490
- Resource Relation:
- Conference: 193. national meeting of the American Chemical Society, Denver, CO, USA, 5 Apr 1987; Other Information: Portions of this document are illegible in microfiche products
- Country of Publication:
- United States
- Language:
- English
Similar Records
A YSO/LSO phoswich array detector for single and coincidence photon imaging
Neutron detection and multiplicity counting using a boron-loaded plastic scintillator/bismuth germanate phoswich detector array
An array of virtual Frisch-grid CdZnTe detectors and a front-end application-specific integrated circuit for large-area position-sensitive gamma-ray cameras
Journal Article
·
Mon Jun 01 00:00:00 EDT 1998
· IEEE Transactions on Nuclear Science
·
OSTI ID:7057982
+3 more
Neutron detection and multiplicity counting using a boron-loaded plastic scintillator/bismuth germanate phoswich detector array
Technical Report
·
Sun Mar 01 00:00:00 EST 1998
·
OSTI ID:7057982
An array of virtual Frisch-grid CdZnTe detectors and a front-end application-specific integrated circuit for large-area position-sensitive gamma-ray cameras
Journal Article
·
Wed Jul 15 00:00:00 EDT 2015
· Review of Scientific Instruments
·
OSTI ID:7057982
+14 more