Title: Evaluation of the DWPF chemical process cell sample condenser in the integrated DWPF melter system

Technical Report ·
DOI:https://doi.org/10.2172/6992725· OSTI ID:6992725

An on-line Analysis system for hydrogen is being added to the Chemical Processing Cell (CPC) in DWPF to ensure that the process does not operate above the lower flammable limit (LFL). The method chosen to measure hydrogen during cold runs is gas chromatography (GC). In order for the GCs to analyze the offgas exiting the SRAT and SME condensers, an additional condenser is required to reduce the dew point of tho sample to below the lowest ambient temperature expected so that no liquid water will enter the GCs. This temperature was chosen to be 10[degrees]C.