skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Microchannel plate EUV detectors for the extreme ultraviolet explorer

Conference · · IEEE Trans. Nucl. Sci.; (United States)
OSTI ID:6984692

The design and operating characteristics of the prototype imaging microchannel plate (MCP) detector for the Extreme Ultraviolet Explorer (EUVE) Satellite are discussed. The authors show that this detector has achieved high position resolution performance (> 512X512 pixels) and has low (< 1%) image distortion. In addition, the channel plate scheme used has tight pulse height distributions (< 40% FWHM) for UV radiation and displays low (< .2 cnt cm/sup -2/ sec/sup -1/) dark background counting rates. The authors also describe work that has been done on EUV filters in relation to the envisaged filter and photocathode complement.

Research Organization:
Space Sciences Lab., Univ. of California, Berkeley, CA 94720
OSTI ID:
6984692
Report Number(s):
CONF-831015-
Journal Information:
IEEE Trans. Nucl. Sci.; (United States), Vol. 31:1; Conference: Nuclear science symposium, San Francisco, CA, USA, 19 Oct 1983
Country of Publication:
United States
Language:
English