A comparison of analytic models for estimating dose equivalent rates in shielding with beam spill measurements
Conference
·
OSTI ID:6902301
A comparison of 800-MeV proton beam spill measurements at the Los Alamos Meson Physics Facility (LAMPF) with analytical model calculations of neutron dose equivalent rates (DER) show agreement within factors of 2-3 for simple shielding geometries. The DER estimates were based on a modified Moyer model for transverse angles and a Monte Carlo based forward angle model described in the proceeding paper.
- Research Organization:
- Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
- Sponsoring Organization:
- USDOE; USDOE, Washington, DC (United States)
- DOE Contract Number:
- W-7405-ENG-36
- OSTI ID:
- 6902301
- Report Number(s):
- LA-UR-92-4148; CONF-9210264-1; ON: DE93005426
- Resource Relation:
- Conference: Particle and fields conference, Batavia, IL (United States), 13-17 Oct 1992
- Country of Publication:
- United States
- Language:
- English
Similar Records
A comparison of analytic models for estimating dose equivalent rates in shielding with beam spill measurements
Monte Carlo based formula for estimating penetration of radiation shielding at forward angles
Monte Carlo based formula for estimating penetration of radiation shielding at forward angles
Conference
·
Thu Dec 31 00:00:00 EST 1992
·
OSTI ID:6902301
+2 more
Monte Carlo based formula for estimating penetration of radiation shielding at forward angles
Conference
·
Thu Dec 31 00:00:00 EST 1992
·
OSTI ID:6902301
+2 more
Monte Carlo based formula for estimating penetration of radiation shielding at forward angles
Conference
·
Wed Jan 01 00:00:00 EST 1992
·
OSTI ID:6902301
+2 more
Related Subjects
43 PARTICLE ACCELERATORS
61 RADIATION PROTECTION AND DOSIMETRY
PROTON BEAMS
SHIELDING
DOSE EQUIVALENTS
BEAM BENDING MAGNETS
COMPARATIVE EVALUATIONS
LAMPF LINAC
MATHEMATICAL MODELS
MONTE CARLO METHOD
NEUTRON DETECTION
ACCELERATORS
BEAMS
CALCULATION METHODS
DETECTION
ELECTRICAL EQUIPMENT
ELECTROMAGNETS
EQUIPMENT
EVALUATION
LINEAR ACCELERATORS
MAGNETS
MESON FACTORIES
NUCLEON BEAMS
PARTICLE BEAMS
RADIATION DETECTION
430303* - Particle Accelerators- Experimental Facilities & Equipment
560101 - Biomedical Sciences
Applied Studies- Radiation Effects- Dosimetry & Monitoring- (1992-)
61 RADIATION PROTECTION AND DOSIMETRY
PROTON BEAMS
SHIELDING
DOSE EQUIVALENTS
BEAM BENDING MAGNETS
COMPARATIVE EVALUATIONS
LAMPF LINAC
MATHEMATICAL MODELS
MONTE CARLO METHOD
NEUTRON DETECTION
ACCELERATORS
BEAMS
CALCULATION METHODS
DETECTION
ELECTRICAL EQUIPMENT
ELECTROMAGNETS
EQUIPMENT
EVALUATION
LINEAR ACCELERATORS
MAGNETS
MESON FACTORIES
NUCLEON BEAMS
PARTICLE BEAMS
RADIATION DETECTION
430303* - Particle Accelerators- Experimental Facilities & Equipment
560101 - Biomedical Sciences
Applied Studies- Radiation Effects- Dosimetry & Monitoring- (1992-)