Title: Bolus injections of measured amounts of radioactivity

Abstract

Many time-based radionuclide techniques, such as glomerular filtration rate measurement (GFR), require prompt intravenous delivery of and accurately measured tracer bolus with minimal residual tracer retention at the injection site. The quality assurance aspects of two antecubital vein, quantitative injection techniques were investigated. A flush bolus technique using a tuberculin syringe piggybacked onto a 10-ml saline flush was compared to a single blood pressure cuff injection technique. Scintillation camera data for each technique were compared for bolus duration in the abdominal aorta and for residual activity at the injection site at 5 min. Bolus times were measured as the FWHM of the gamma variate fit to the abdominal aortic regional time-activity curves. Relatively little focal activity was seen in the antecubital injection site following the flush bolus: marked residual activity was seen following the blood pressure cuff injections. The injection site/arm background ratios averaged 1.3 for the flush bolus and 30.1 for the cuff technique. Although both methods allowed accurate in vitro determination of administered radioactivity, only the tuberculin syringe flush bolus technique was acceptable for time-based quantitation because of its superior in vivo characteristics.

Authors:
; ; ;
Publication Date:
Research Org.:
Univ. of Western Ontario, London (Canada)
OSTI Identifier:
6879158
Resource Type:
Journal Article
Resource Relation:
Journal Name: J. Nucl. Med. Technol.; (United States); Journal Volume: 16:1
Country of Publication:
United States
Language:
English
Subject:
62 RADIOLOGY AND NUCLEAR MEDICINE; KIDNEYS; DYNAMIC FUNCTION STUDIES; SCINTISCANNING; RADIOPHARMACEUTICALS; RENAL CLEARANCE; DIAGNOSTIC USES; GLOMERULI; PATIENTS; ULTRAFILTRATION; BODY; CLEARANCE; COUNTING TECHNIQUES; DIAGNOSTIC TECHNIQUES; DRUGS; EXCRETION; FILTRATION; LABELLED COMPOUNDS; ORGANS; RADIOISOTOPE SCANNING; SEPARATION PROCESSES; USES 550601* -- Medicine-- Unsealed Radionuclides in Diagnostics

Citation Formats

Wesolowski, C.A., Hogendoorn, P., Vandierendonck, R., and Driedger, A.A.. Bolus injections of measured amounts of radioactivity. United States: N. p., 1988. Web.
Wesolowski, C.A., Hogendoorn, P., Vandierendonck, R., & Driedger, A.A.. Bolus injections of measured amounts of radioactivity. United States.
Wesolowski, C.A., Hogendoorn, P., Vandierendonck, R., and Driedger, A.A.. 1988. "Bolus injections of measured amounts of radioactivity". United States. doi:.
@article{osti_6879158,
title = {Bolus injections of measured amounts of radioactivity},
author = {Wesolowski, C.A. and Hogendoorn, P. and Vandierendonck, R. and Driedger, A.A.},
abstractNote = {Many time-based radionuclide techniques, such as glomerular filtration rate measurement (GFR), require prompt intravenous delivery of and accurately measured tracer bolus with minimal residual tracer retention at the injection site. The quality assurance aspects of two antecubital vein, quantitative injection techniques were investigated. A flush bolus technique using a tuberculin syringe piggybacked onto a 10-ml saline flush was compared to a single blood pressure cuff injection technique. Scintillation camera data for each technique were compared for bolus duration in the abdominal aorta and for residual activity at the injection site at 5 min. Bolus times were measured as the FWHM of the gamma variate fit to the abdominal aortic regional time-activity curves. Relatively little focal activity was seen in the antecubital injection site following the flush bolus: marked residual activity was seen following the blood pressure cuff injections. The injection site/arm background ratios averaged 1.3 for the flush bolus and 30.1 for the cuff technique. Although both methods allowed accurate in vitro determination of administered radioactivity, only the tuberculin syringe flush bolus technique was acceptable for time-based quantitation because of its superior in vivo characteristics.},
doi = {},
journal = {J. Nucl. Med. Technol.; (United States)},
number = ,
volume = 16:1,
place = {United States},
year = 1988,
month = 3
}
  • Purpose: Increasingly, brass mesh bolus is used to insure dosimetric coverage of the skin for patients treated post-mastectomy for breast cancer. Contribution of photoelectrons from interactions between the bolus and the primary beam increases dose superficially without affecting dose at greater depths. We present our experience using brass mesh bolus – including patients for whom the bolus was dosimetrically inadequate – along with analysis of relevant patient-specific parameters. Methods: Optically-stimulated luminescent dosimeters (OSLDs) were used to determine the effect of the bolus for 15 patients. They were positioned beneath the bolus within the tangent fields at three positions: 1.5–3cm insidemore » the medial and lateral field edges, and midway between the two. All OSLDs were midfield in the cranial-caudal direction. The measurements were compared with patient-specific parameters including separation, chest wall/breast tissue thickness, beam angle incidence, and planned surface dose. Results: The average OSLD measurement at the medial field edge, midfield, and lateral field edge position was 86.8%, 101.8%, and 92.8% of the prescription dose, respectively. A measurement for one patient was low enough (77.0%) to warrant a switch to an alternative type of bolus. Anatomic parameters were analyzed to investigate the low dose in this case, not observed in the planning system. The patient was observed to have a thin chest wall and very oblique beam angles. A second patient was also switched to an alternative type of bolus due to her being high risk and treated with an electron patch that extended onto the breast. Conclusion: Brass mesh bolus increases dose superficially while leaving dose at greater depths unaffected. However, our results suggest that this effect may be insufficient in patients with a thin chest wall or very oblique beam angles. More data and analysis is necessary to proactively identify patients for whom brass mesh bolus is effective.« less
  • Evaluation of erythropoietic function by the use of radioactive labels is discussed in relation to the capturerecapture method for investigating changes in wild animal populations. Mathematical equations are derived and applied to experimental data. It is shown how estimates of the rate of creation at isolated instants may be made without actually fitting the differential equation for population growth, and without assuming the form of the mortality function of the cells. The methods proposed are based on the comparison of the value and gradient of radioactivity of samples of cells immediately before and after a number (possibly one) of successivemore » injections, and minimize the number of injections necessary. (H.H.D.)« less
  • Workers in coke oven plants have a higher incidence of lung cancer than the general population. They are exposed to a variety of chemicals, in particular the polycyclic aromatic hydrocarbons (PAH), including benzo(a)pyrene. To evaluate the genotoxic effects of PAH exposure, air samples and urine samples were analyzed for PAH by capillary gas chromatography and high-performance liquid chromatography, respectively. Since benzo(a)pyrene is activated to 7 beta,8 alpha-dihydroxy-(9 alpha,10 alpha)-epoxy-7,8,9,10-tetrahydrobenzo(a)pyrene (BPDE) and binds to DNA, we have used ultrasensitive enzymatic radioimmunoassay and synchronous fluorescence spectrophotometry to measure BPDE-DNA adducts in lymphocyte DNA. The results show that workers were exposed to highmore » concentrations of atmospheric PAH. However, the mean PAH exposure levels are reduced 60% when the workers wore masks during work. When compared to exposure levels, the urinary excretion of PAH was relatively low. Approximately one-third of the workers had detectable putative BPDE-DNA adducts in lymphocytes by ultrasensitive enzymatic radioimmunoassay, and 10% of the samples had emission peaks at 379 nm by synchronous fluorescence spectrophotometry. The four most positive samples were the same in both of the assays. Antibodies to an epitope(s) on BPDE-DNA were found in the sera of approximately one-third of the workers. Detection of DNA adducts and antibodies to these adducts are internal indicators of exposure to benzo(a)pyrene.« less
  • A method was developed for determining small amounts of water and hydroxyl groups on the surface of highly disperse bodies, without destruction of the latter, by deuterium exchange with heavy water. The exchange products are converted to hydrogen and the isotopic composition of the hydrogen is determined mass spectrometrically. Results of good reproducibility were obtained. The method is applicable for the determination in various materials of water accessible to exchange reaction, for instance such as that present on the surfaces of adsorbents, fillers, pigments, synthetic polymers, and many biopolymers. (auth)