Tuning permanent magnets with adjustable field clamps
Conference
·
OSTI ID:6649661
The effective length of a permanent-magnet assembly can be varied by adjusting the geometrical parameters of a field clamp. This paper presents measurements on a representative dipole and quadrupole as the field clamp is withdrawn axially or radially. The detailed behavior depends upon the magnet multipolarity and geometry. As a rule-of-thumb, a 3-mm-thick iron plate placed at one end plane of the magnet will shorten the length by one-third of the magnet bore radius.
- Research Organization:
- Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
- DOE Contract Number:
- W-7405-ENG-36
- OSTI ID:
- 6649661
- Report Number(s):
- LA-UR-87-646; CONF-870302-47; ON: DE87007467
- Resource Relation:
- Conference: Particle accelerator conference, Washington, DC, USA, 16 Mar 1987; Other Information: Paper copy only, copy does not permit microfiche production
- Country of Publication:
- United States
- Language:
- English
Similar Records
Adjustable permanent quadrupoles for the next linear collider
Adjustable Permanent Quadrupoles for the Next Linear Collider
Adjustable Permanent Quadrupoles Using Rotating Magnet Material Rods for the Next Linear Collider.