Flow cytometry discriminates particle associated fluorescence from the fluorescence of the surrounding medium. It permits assemblies of macromolecular complexes on beads or cells to be detected in real-time with precision and specificity. The authors have investigated two types of robust sample handling systems which provide sub-second resolution and high throughput: (1) mixers which use stepper-motor driven syringes to initiate chemical reactions in msec time frames; and (2) flow injection controllers with valves and automated syringes used in chemical process control. In the former system, the authors used fast valves to overcome the disparity between mixing 100 {micro}ls of sample in 100 msecs and delivering sample to a flow cytometer at 1 {micro}l/sec. Particles were detected within 100 msec after mixing, but turbulence was created which lasted for 1 sec after injection of the sample into the flow cytometer. They used optical criteria to discriminate particles which were out of alignment due to the turbulent flow. Complex sample handling protocols involving multiple mixing steps and sample dilution have also been achieved. With the latter system they were able to automate sample handling and delivery with intervals of a few seconds. The authors used a fluidic approach to defeat turbulence caused by sample introduction. By controlling both sheath and sample with individual syringes, the period of turbulence was reduced to {approximately} 200 msecs. Automated sample handling and sub-second resolution should permit broad analytical and diagnostic applications of flow cytometry.

Research Organization:
Los Alamos National Lab., National Flow Cytometry Resource, NM (United States)
Sponsoring Organization:
National Insts. of Health, Bethesda, MD (United States)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
663512
Report Number(s):
LA-UR-98-287; CONF-980117-; ON: DE98003496; TRN: AHC29818%%349
Resource Relation:
Conference: BIOS `98: an international symposium on biomedical optics, San Jose, CA (United States), 24-30 Jan 1998; Other Information: PBD: [1998]
Country of Publication:
United States
Language:
English