skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: LOFT CIS analysis penetration S-11B 12'' H and V duct

Technical Report ·
DOI:https://doi.org/10.2172/6607605· OSTI ID:6607605

The 12 in. H and V Duct and related piping outside the LOFT containment and connected to containment penetration S-11B was analyzed to ASME Code, Subsection NC (Class 2) criteria. This duct is part of the Containment Isolation System. The model considered the duct from the containment O.D. outward through the second isolation valve. Results of this analysis show that this section of the line will meet Class 2 requirements without modification.

Research Organization:
Idaho National Lab. (INL), Idaho Falls, ID (United States)
DOE Contract Number:
EY-76-C-07-1570
OSTI ID:
6607605
Report Number(s):
LTR-123-8; TRN: 79-000189
Resource Relation:
Other Information: Portions of document are illegible
Country of Publication:
United States
Language:
English