Title: LOFT L2-3 scoping blowdown experiment safety analyses A, B, C, CD, CE, and CF

Abstract

The consequences of various postulated single failures during loss-of-fluid test (LOFT) Loss-of-Coolant Experiment (LOCE) L2-3 were analyzed for the LOCE L2-3 blowdown scoping experiment safety analysis (ESA). The following six of the LOCE L2-3 blowdown scoping ESA were performed: (1) Analysis A--failure of high-pressure injection system (HPIS) A; (2) Analysis B--failure of accumulator A; (3) Analysis C--failure of low-pressure injection system (LPIS) A, assuming accumulator A initial conditions of 550 psig and 84/sup 0/F; (4) Analysis CD--failure of LPIS A, assuming accumulator A initial conditions of 550 psig and 150/sup 0/F; (5) Analysis CE--failure of LPIS A, assuming accumulator A initial conditions of 650 psig and 150/sup 0/F; and (6) Analysis CF--failure of LPIS A, assuming accumulator A initial conditions of 650 psig and 115/sup 0/F. RELAP4/MOD5 models with conservative off-nominal initial conditions, and evaluation model (EM) options were used during the blowdown-refill phase of the analyses. RELAP4/MOD6 models with conservative input parameters and code options selected were used for the reflood phase of the analyses.

Authors:
; ; ;
Publication Date:
Research Org.:
Idaho National Engineering Lab., Idaho Falls (USA)
OSTI Identifier:
6525820
Report Number(s):
LTR-10-45
TRN: 79-005141
DOE Contract Number:  
EY-76-C-07-1570
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
22 GENERAL STUDIES OF NUCLEAR REACTORS; 21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; BLOWDOWN; HEAT TRANSFER; HYDRAULICS; LOFT REACTOR; PWR TYPE REACTORS; ACCUMULATORS; COMPUTER CALCULATIONS; FAILURES; HPCI; LOSS OF COOLANT; LPCI; R CODES; REACTOR SAFETY EXPERIMENTS; ACCIDENTS; COMPUTER CODES; CONTAINERS; ECCS; ENERGY TRANSFER; ENGINEERED SAFETY SYSTEMS; FLUID MECHANICS; MECHANICS; REACTOR ACCIDENTS; REACTOR PROTECTION SYSTEMS; REACTORS; RESEARCH AND TEST REACTORS; TANK TYPE REACTORS; TANKS; TEST REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS; 220900* - Nuclear Reactor Technology- Reactor Safety; 210200 - Power Reactors, Nonbreeding, Light-Water Moderated, Nonboiling Water Cooled; 220600 - Nuclear Reactor Technology- Research, Test & Experimental Reactors

Citation Formats

Perryman, J L, Keeler, C D, Good, E G, and Saukkoriipi, L O. LOFT L2-3 scoping blowdown experiment safety analyses A, B, C, CD, CE, and CF. United States: N. p., 1978. Web.
Perryman, J L, Keeler, C D, Good, E G, & Saukkoriipi, L O. LOFT L2-3 scoping blowdown experiment safety analyses A, B, C, CD, CE, and CF. United States.
Perryman, J L, Keeler, C D, Good, E G, and Saukkoriipi, L O. 1978. "LOFT L2-3 scoping blowdown experiment safety analyses A, B, C, CD, CE, and CF". United States.
@article{osti_6525820,
title = {LOFT L2-3 scoping blowdown experiment safety analyses A, B, C, CD, CE, and CF},
author = {Perryman, J L and Keeler, C D and Good, E G and Saukkoriipi, L O},
abstractNote = {The consequences of various postulated single failures during loss-of-fluid test (LOFT) Loss-of-Coolant Experiment (LOCE) L2-3 were analyzed for the LOCE L2-3 blowdown scoping experiment safety analysis (ESA). The following six of the LOCE L2-3 blowdown scoping ESA were performed: (1) Analysis A--failure of high-pressure injection system (HPIS) A; (2) Analysis B--failure of accumulator A; (3) Analysis C--failure of low-pressure injection system (LPIS) A, assuming accumulator A initial conditions of 550 psig and 84/sup 0/F; (4) Analysis CD--failure of LPIS A, assuming accumulator A initial conditions of 550 psig and 150/sup 0/F; (5) Analysis CE--failure of LPIS A, assuming accumulator A initial conditions of 650 psig and 150/sup 0/F; and (6) Analysis CF--failure of LPIS A, assuming accumulator A initial conditions of 650 psig and 115/sup 0/F. RELAP4/MOD5 models with conservative off-nominal initial conditions, and evaluation model (EM) options were used during the blowdown-refill phase of the analyses. RELAP4/MOD6 models with conservative input parameters and code options selected were used for the reflood phase of the analyses.},