skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Functional design criteria, Project W-211, Initial Tank Retrieval Systems. Revision 1

Technical Report ·
DOI:https://doi.org/10.2172/65029· OSTI ID:65029

This document provides the technical baseline for retrieval of waste from ten double-shell tanks in the SY, AN, AP, AW, AY, and AZ tank farms. In order to retrieve waste from these tanks, systems are needed to mix the sludge with the supernate and pump the waste mixture from the tank. For 101-SY, the existing mitigation pump will be used to mix the waste and Project W-211 will provide for waste removal. The retrieval scope for the other nine tanks includes both the waste mixing and removal functions.

Research Organization:
Westinghouse Hanford Co., Richland, WA (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC06-87RL10930
OSTI ID:
65029
Report Number(s):
WHC-SD-W211-FDC-001-Rev.1; ON: DE95007197; TRN: 95:014059
Resource Relation:
Other Information: PBD: 7 Feb 1995
Country of Publication:
United States
Language:
English