skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Maintaining optimum fluorescent lamp performance under elevated temperature conditions

Conference ·
OSTI ID:6458232

This paper describes a new technique for optimizing fluorescent lamp performance under elevated temperature conditions. This approach uses a thermo-electric Peltier device to produce a localized cold spot temperature of approximately 40/sup 0/C, allowing the lamps to maintain maximum light output and efficacy independent of prevailing ambient temperatures inside a luminaire. Experimental data show that a 20% increase in light output and a 10% increase in efficacy over typical lamp performance in a warm fixture environment can be obtained using this device. Only 0.25 watts must be supplied to the Peltier device to produce these results.

Research Organization:
Lawrence Berkeley Lab., CA (USA)
DOE Contract Number:
AC03-76SF00098
OSTI ID:
6458232
Report Number(s):
LBL-21004; CONF-8608179-1; ON: DE87009155
Resource Relation:
Conference: Annual Illuminating Engineering Society conference, Boston, MA, USA, 16 Aug 1986; Other Information: Portions of this document are illegible in microfiche products
Country of Publication:
United States
Language:
English