The laser beams irradiating a target at the Nova laser facility comprise a set of ten simultaneous events. Two streak cameras, whose resolutions are 40 ps, record the power history for each beam, five beams to a camera; their time bases are cross-timed with a fiducial pulse. Analysis of data recorded for target experiments conducted over a six month period show the precision for cross-timing signals between two streak cameras to be {plus minus}9 ps and for characterizing a single temporal feature of a pulse to be {plus minus}5 ps. Beam synchronization at the end of six months was within 20 ps of the synchronization at the beginning of the experiments. A beam timing shift greater than 25 ps can be detected on a single laser shot; shifts of 10 to 20 ps require several shots to detect. 2 refs., 6 figs.

Research Organization:
Lawrence Livermore National Lab., CA (USA)
Sponsoring Organization:
DOE/DP
DOE Contract Number:
W-7405-ENG-48
OSTI ID:
6428341
Report Number(s):
UCRL-JC-104877; CONF-900756-55; ON: DE91005266
Resource Relation:
Conference: 34. SPIE annual international technical symposium on optical and optoelectronic applied science and engineering, San Diego, CA (USA), 8-13 Jul 1990