Title: Large-acceptance-angle gridded analyzers in an axial magnetic field

Abstract

Electrostatic retarding-potential gridded analyzers have been used to measure the current and the axial energy distributions of ions escaping along magnetic field lines in the 2XIIB magnetic mirror fusion experiment at Lawerence Livermore National Laboratory (LLNL). Three analyzers are discussed: a large scanning analyzer with a movable entrance aperture that can measure ion or electron losses from a different segment of the plasma diameter on each shot, a smaller analyzer that mounts in 5-cm-diam ports, and a multicollector analyzer that can continuously measure losses from the entire plasma diameter.

Authors:
Publication Date:
Research Org.:
Lawrence Livermore National Lab., CA (USA)
OSTI Identifier:
6378514
Report Number(s):
UCRL-52981
ON: DE81025122; TRN: 81-012958
DOE Contract Number:
W-7405-ENG-48
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
70 PLASMA PHYSICS AND FUSION TECHNOLOGY; 2X DEVICES; ENERGY LOSSES; ELECTROSTATIC ANALYZERS; PERFORMANCE; BEAM CURRENTS; ELECTRIC POTENTIAL; ELECTRODES; ION EMISSION; BEAM ANALYZERS; CURRENTS; LOSSES; MAGNETIC MIRRORS; OPEN PLASMA DEVICES; THERMONUCLEAR DEVICES; 700102* - Fusion Energy- Plasma Research- Diagnostics

Citation Formats

Molvik, A.W.. Large-acceptance-angle gridded analyzers in an axial magnetic field. United States: N. p., 1981. Web. doi:10.2172/6378514.
Molvik, A.W.. Large-acceptance-angle gridded analyzers in an axial magnetic field. United States. doi:10.2172/6378514.
Molvik, A.W.. Mon . "Large-acceptance-angle gridded analyzers in an axial magnetic field". United States. doi:10.2172/6378514. https://www.osti.gov/servlets/purl/6378514.
@article{osti_6378514,
title = {Large-acceptance-angle gridded analyzers in an axial magnetic field},
author = {Molvik, A.W.},
abstractNote = {Electrostatic retarding-potential gridded analyzers have been used to measure the current and the axial energy distributions of ions escaping along magnetic field lines in the 2XIIB magnetic mirror fusion experiment at Lawerence Livermore National Laboratory (LLNL). Three analyzers are discussed: a large scanning analyzer with a movable entrance aperture that can measure ion or electron losses from a different segment of the plasma diameter on each shot, a smaller analyzer that mounts in 5-cm-diam ports, and a multicollector analyzer that can continuously measure losses from the entire plasma diameter.},
doi = {10.2172/6378514},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Mon Jun 01 00:00:00 EDT 1981},
month = {Mon Jun 01 00:00:00 EDT 1981}
}

Technical Report: