Title: Evaluation of exposure conditions for the water-side corrosion test of a sodium heated steam generator evaporator model employing a duplex tube (2160 hours at critical heat flux - phase III SSGM tests). [LMFBR]

Abstract

This report describes the specialized corrosion test water steam loop, test procedures, test conditions, and test results. A complete water chemistry and thermal hydraulic performance history is given and evaluated for the Phase III test program. The movement of the dryout location and the heat flux variations in pre- and post-critical heat flux regions are documented and analyzed. On seven occasions during the course of the test program to date, the operating conditions drifted from the CHF reference Phase III operation in the dryout regime into the DNB regime. The corresponding corrosion mechanism experienced differing exposure conditions on these occasions. CHF sensitivity to this apparent drift behavior is evaluated.

Authors:
; ;
Publication Date:
Research Org.:
Westinghouse Electric Corp., Tampa, FL (USA). Tampa Div.
OSTI Identifier:
6332265
Report Number(s):
WNET-123
ON: DE81026909
DOE Contract Number:  
AC03-76SF00962
Resource Type:
Technical Report
Country of Publication:
United States
Language:
English
Subject:
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; LMFBR TYPE REACTORS; STEAM GENERATORS; PERFORMANCE TESTING; TUBES; CORROSION; CRITICAL HEAT FLUX; TEST FACILITIES; WATER CHEMISTRY; BOILERS; BREEDER REACTORS; CHEMICAL REACTIONS; CHEMISTRY; EPITHERMAL REACTORS; FAST REACTORS; FBR TYPE REACTORS; HEAT FLUX; LIQUID METAL COOLED REACTORS; REACTORS; TESTING; VAPOR GENERATORS; 210500* - Power Reactors, Breeding

Citation Formats

Waszink, R.P., Hwang, J.Y., and Efferding, L.E.. Evaluation of exposure conditions for the water-side corrosion test of a sodium heated steam generator evaporator model employing a duplex tube (2160 hours at critical heat flux - phase III SSGM tests). [LMFBR]. United States: N. p., 1975. Web. doi:10.2172/6332265.
Waszink, R.P., Hwang, J.Y., & Efferding, L.E.. Evaluation of exposure conditions for the water-side corrosion test of a sodium heated steam generator evaporator model employing a duplex tube (2160 hours at critical heat flux - phase III SSGM tests). [LMFBR]. United States. doi:10.2172/6332265.
Waszink, R.P., Hwang, J.Y., and Efferding, L.E.. Mon . "Evaluation of exposure conditions for the water-side corrosion test of a sodium heated steam generator evaporator model employing a duplex tube (2160 hours at critical heat flux - phase III SSGM tests). [LMFBR]". United States. doi:10.2172/6332265. https://www.osti.gov/servlets/purl/6332265.
@article{osti_6332265,
title = {Evaluation of exposure conditions for the water-side corrosion test of a sodium heated steam generator evaporator model employing a duplex tube (2160 hours at critical heat flux - phase III SSGM tests). [LMFBR]},
author = {Waszink, R.P. and Hwang, J.Y. and Efferding, L.E.},
abstractNote = {This report describes the specialized corrosion test water steam loop, test procedures, test conditions, and test results. A complete water chemistry and thermal hydraulic performance history is given and evaluated for the Phase III test program. The movement of the dryout location and the heat flux variations in pre- and post-critical heat flux regions are documented and analyzed. On seven occasions during the course of the test program to date, the operating conditions drifted from the CHF reference Phase III operation in the dryout regime into the DNB regime. The corresponding corrosion mechanism experienced differing exposure conditions on these occasions. CHF sensitivity to this apparent drift behavior is evaluated.},
doi = {10.2172/6332265},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Mon Dec 01 00:00:00 EST 1975},
month = {Mon Dec 01 00:00:00 EST 1975}
}