Research and Development Toward a 4.5-1.5 {Angstrom} Linac Coherent Light Source (LCLS) at SLAC
Abstract
In recent years significant studies have been initiated on the feasibility of utilizing a portion of the 3km S-band accelerator at SLAC to drive a short wavelength (4.5-1.5 A) Linac Coherent Light Source (LCLS), a Free Electron Laser (FEL) operating in the Self- Amplified Spontaneous Emission (SASE) regime. Electron beam requirements for single-pass saturation in a minimal time include: (1) a peak current in the 7 kA range, (2) a relative energy spread of {lt}0.05%, and (3) a transverse emittance, {epsilon}[r-m], approximating the diffraction limit condition {epsilon} = {lambda} / 4{pi}, where lambda(m) is the output wavelength. Requirements on the insertion device include field error levels of 0.02% for keeping the electron bunch centered on and in phase with the amplified photons, and a focusing beta of 8 m/rad for inhibiting the dilution of its transverse density. Although much progress has been made in developing individual components and beam processing techniques necessary for LCLS operation down to approx. 20 A, a substantial amount of research and development is still required in a number of theoretical and experimental areas leading to the construction and operation of a 4.5-1.5 A LCLS. In this paper we report on a research and development programmore »
- Authors:
-
- and others
- Publication Date:
- Research Org.:
- SLAC National Accelerator Lab., Menlo Park, CA (United States)
- Sponsoring Org.:
- USDOE Office of Energy Research, Washington, DC (United States)
- OSTI Identifier:
- 628014
- Report Number(s):
- SLAC-PUB-95-6994; CONF-9508156-
ON: DE97009078; TRN: 98:006926
- DOE Contract Number:
- AC03-76SF00515
- Resource Type:
- Conference
- Resource Relation:
- Conference: 17. international free electron laser conference, New York, NY (United States), 21-25 Aug 1995; Other Information: PBD: Aug 1995
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 43 PARTICLE ACCELERATORS; ELECTRON BEAMS; FREE ELECTRON LASERS; PHOTOCATHODES; WIGGLER MAGNETS; USES; TESTING; COMPUTERIZED SIMULATION; X RADIATION
Citation Formats
Tatchyn, R, Arthur, J, and Baltay, M. Research and Development Toward a 4.5-1.5 {Angstrom} Linac Coherent Light Source (LCLS) at SLAC. United States: N. p., 1995.
Web.
Tatchyn, R, Arthur, J, & Baltay, M. Research and Development Toward a 4.5-1.5 {Angstrom} Linac Coherent Light Source (LCLS) at SLAC. United States.
Tatchyn, R, Arthur, J, and Baltay, M. 1995.
"Research and Development Toward a 4.5-1.5 {Angstrom} Linac Coherent Light Source (LCLS) at SLAC". United States. https://www.osti.gov/servlets/purl/628014.
@article{osti_628014,
title = {Research and Development Toward a 4.5-1.5 {Angstrom} Linac Coherent Light Source (LCLS) at SLAC},
author = {Tatchyn, R and Arthur, J and Baltay, M},
abstractNote = {In recent years significant studies have been initiated on the feasibility of utilizing a portion of the 3km S-band accelerator at SLAC to drive a short wavelength (4.5-1.5 A) Linac Coherent Light Source (LCLS), a Free Electron Laser (FEL) operating in the Self- Amplified Spontaneous Emission (SASE) regime. Electron beam requirements for single-pass saturation in a minimal time include: (1) a peak current in the 7 kA range, (2) a relative energy spread of {lt}0.05%, and (3) a transverse emittance, {epsilon}[r-m], approximating the diffraction limit condition {epsilon} = {lambda} / 4{pi}, where lambda(m) is the output wavelength. Requirements on the insertion device include field error levels of 0.02% for keeping the electron bunch centered on and in phase with the amplified photons, and a focusing beta of 8 m/rad for inhibiting the dilution of its transverse density. Although much progress has been made in developing individual components and beam processing techniques necessary for LCLS operation down to approx. 20 A, a substantial amount of research and development is still required in a number of theoretical and experimental areas leading to the construction and operation of a 4.5-1.5 A LCLS. In this paper we report on a research and development program underway and in planning at SLAC for addressing critical questions in these areas.},
doi = {},
url = {https://www.osti.gov/biblio/628014},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Tue Aug 01 00:00:00 EDT 1995},
month = {Tue Aug 01 00:00:00 EDT 1995}
}