Title: Steam generator tube rupture in an experimental facility scaled from a pressurized water reactor

Conference ·
OSTI ID:6278784

Results from an experimental investigation of steam generator tube rupture in the Semiscale Mod-2B system are presented. From the experimental results, the characteristic system response signature for a wide range of number of tubes ruptured has been described. The tube rupture was assumed to occur during normal full power operation (15.6 MPa system pressure, 37/sup 0/K core differential temperature). In addition, recovery scenarios involving operator actions were examined. The recovery scenarios included use of pressurizer auxiliary spray and internal heaters, steam generator feed and steam, primary feed and bleed, and main cooling pump operation. Recovery scenarios suggested by typical US pressurized water reactor emergency operating procedures were followed.

Research Organization:
Idaho National Engineering Lab., Idaho Falls (USA)
DOE Contract Number:
AC07-76ID01570
OSTI ID:
6278784
Report Number(s):
EGG-M-04184; CONF-841014-2; ON: DE85003427
Resource Relation:
Conference: International conference on nuclear and radiochemistry, Lindau, Bodensee, F.R. Germany, 8 Oct 1984; Other Information: Portions are illegible in microfiche products
Country of Publication:
United States
Language:
English