Title: Rf phase measurement at PHERMEX (Pulsed High Energy Radiographic Machine Emitting X-Rays) using time-to-digital converters

Conference ·
OSTI ID:6275515

Recent advances in time-to-digital converters (TDCs) have made 50-MHz rf phase measurement possible without the use of double-balanced mixers. These advances allow zero crossing discriminators to be used in conjunction with fast CAMAC TDCs to make amplitude-independent phase measurements. This method uses a time interval proportional to the phase angle, thus eliminating any of the calculations and calibration required with double-balanced mixers. 4 refs., 1 fig., 1 tab.

Research Organization:
Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
6275515
Report Number(s):
LA-UR-89-973; CONF-890335-16; ON: DE89009268
Resource Relation:
Conference: 13. particle accelerator conference, Chicago, IL, USA, 20 Mar 1989; Other Information: Portions of this document are illegible in microfiche products
Country of Publication:
United States
Language:
English

Similar Records

A High Resolution, Multi-stop, Time-to-Digital Converter for Nuclear Time-of-Flight Measurements
Journal Article · Sun Jan 01 00:00:00 EST 2006 · Nuclear Instruments and Methods · OSTI ID:6275515

A 250-ps time-resolution CMOS multihit time-to-digital converter for nuclear physics experiments
Journal Article · Thu Apr 01 00:00:00 EST 1999 · IEEE Transactions on Nuclear Science · OSTI ID:6275515

MTD 132; A new sub-nanosecond multi-hit CMOS time-to-digital converter
Journal Article · Mon Apr 01 00:00:00 EST 1991 · IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:6275515