skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Detection of mass 16 241 ions by Fourier-transform mass spectrometry

Abstract

An independent investigation is reported of the mass range of FTMS (Fourier-Transform mass spectroscopy) utilizing Cs DI to measure positive and negative cesium iodide cluster ions of masses as high as 16241 daltons, the present low frequency limit of the detection system. 34 references, 1 figure.

Authors:
; ; ; ; ;
Publication Date:
Research Org.:
Cornell Univ., Ithaca, NY
OSTI Identifier:
6270962
DOE Contract Number:  
AS05-82ER13023
Resource Type:
Journal Article
Journal Name:
Anal. Chem.; (United States)
Additional Journal Information:
Journal Volume: 58:2
Country of Publication:
United States
Language:
English
Subject:
37 INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY; CESIUM IODIDES; MASS SPECTROSCOPY; POLYMERS; CESIUM IONS; EXPERIMENTAL DATA; FOURIER ANALYSIS; ION BEAMS; QUANTITATIVE CHEMICAL ANALYSIS; ALKALI METAL COMPOUNDS; BEAMS; CESIUM COMPOUNDS; CHARGED PARTICLES; CHEMICAL ANALYSIS; DATA; HALIDES; HALOGEN COMPOUNDS; INFORMATION; INORGANIC PHOSPHORS; IODIDES; IODINE COMPOUNDS; IONS; NUMERICAL DATA; PHOSPHORS; SPECTROSCOPY; 400104* - Spectral Procedures- (-1987)

Citation Formats

Amster, I J, McLafferty, F W, Castro, M E, Russell, D H, Cody, Jr, R B, and Ghaderi, S. Detection of mass 16 241 ions by Fourier-transform mass spectrometry. United States: N. p., 1986. Web.
Amster, I J, McLafferty, F W, Castro, M E, Russell, D H, Cody, Jr, R B, & Ghaderi, S. Detection of mass 16 241 ions by Fourier-transform mass spectrometry. United States.
Amster, I J, McLafferty, F W, Castro, M E, Russell, D H, Cody, Jr, R B, and Ghaderi, S. 1986. "Detection of mass 16 241 ions by Fourier-transform mass spectrometry". United States.
@article{osti_6270962,
title = {Detection of mass 16 241 ions by Fourier-transform mass spectrometry},
author = {Amster, I J and McLafferty, F W and Castro, M E and Russell, D H and Cody, Jr, R B and Ghaderi, S},
abstractNote = {An independent investigation is reported of the mass range of FTMS (Fourier-Transform mass spectroscopy) utilizing Cs DI to measure positive and negative cesium iodide cluster ions of masses as high as 16241 daltons, the present low frequency limit of the detection system. 34 references, 1 figure.},
doi = {},
url = {https://www.osti.gov/biblio/6270962}, journal = {Anal. Chem.; (United States)},
number = ,
volume = 58:2,
place = {United States},
year = {Sat Feb 01 00:00:00 EST 1986},
month = {Sat Feb 01 00:00:00 EST 1986}
}