Detection of mass 16 241 ions by Fourier-transform mass spectrometry
Abstract
An independent investigation is reported of the mass range of FTMS (Fourier-Transform mass spectroscopy) utilizing Cs DI to measure positive and negative cesium iodide cluster ions of masses as high as 16241 daltons, the present low frequency limit of the detection system. 34 references, 1 figure.
- Authors:
- Publication Date:
- Research Org.:
- Cornell Univ., Ithaca, NY
- OSTI Identifier:
- 6270962
- DOE Contract Number:
- AS05-82ER13023
- Resource Type:
- Journal Article
- Journal Name:
- Anal. Chem.; (United States)
- Additional Journal Information:
- Journal Volume: 58:2
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 37 INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY; CESIUM IODIDES; MASS SPECTROSCOPY; POLYMERS; CESIUM IONS; EXPERIMENTAL DATA; FOURIER ANALYSIS; ION BEAMS; QUANTITATIVE CHEMICAL ANALYSIS; ALKALI METAL COMPOUNDS; BEAMS; CESIUM COMPOUNDS; CHARGED PARTICLES; CHEMICAL ANALYSIS; DATA; HALIDES; HALOGEN COMPOUNDS; INFORMATION; INORGANIC PHOSPHORS; IODIDES; IODINE COMPOUNDS; IONS; NUMERICAL DATA; PHOSPHORS; SPECTROSCOPY; 400104* - Spectral Procedures- (-1987)
Citation Formats
Amster, I J, McLafferty, F W, Castro, M E, Russell, D H, Cody, Jr, R B, and Ghaderi, S. Detection of mass 16 241 ions by Fourier-transform mass spectrometry. United States: N. p., 1986.
Web.
Amster, I J, McLafferty, F W, Castro, M E, Russell, D H, Cody, Jr, R B, & Ghaderi, S. Detection of mass 16 241 ions by Fourier-transform mass spectrometry. United States.
Amster, I J, McLafferty, F W, Castro, M E, Russell, D H, Cody, Jr, R B, and Ghaderi, S. 1986.
"Detection of mass 16 241 ions by Fourier-transform mass spectrometry". United States.
@article{osti_6270962,
title = {Detection of mass 16 241 ions by Fourier-transform mass spectrometry},
author = {Amster, I J and McLafferty, F W and Castro, M E and Russell, D H and Cody, Jr, R B and Ghaderi, S},
abstractNote = {An independent investigation is reported of the mass range of FTMS (Fourier-Transform mass spectroscopy) utilizing Cs DI to measure positive and negative cesium iodide cluster ions of masses as high as 16241 daltons, the present low frequency limit of the detection system. 34 references, 1 figure.},
doi = {},
url = {https://www.osti.gov/biblio/6270962},
journal = {Anal. Chem.; (United States)},
number = ,
volume = 58:2,
place = {United States},
year = {Sat Feb 01 00:00:00 EST 1986},
month = {Sat Feb 01 00:00:00 EST 1986}
}
Other availability
Save to My Library
You must Sign In or Create an Account in order to save documents to your library.